Nortel 1000 Hardware Installation Manual page 31

Application gateway
Table of Contents

Advertisement

Set the COM port on the maintenance terminal as follows:
b.
Terminal type: VT100
Speed: 19200
Data bits: 8
Parity: none
Stop bits: 1
Flow control: hardware
The Application Gateway is shipped with the Admin/Serial port
Note
set to 19200 Bit/s. That setting provides access to the boot
sequence, which you will need to change later in this procedure.
Connect the Application Gateway power cord.
4
Check that the power cord is the type required in the region where the
a.
Application Gateway is used.
Do not modify or use the supplied AC power cord if it is not the
correct type. Refer to Installation and Configuration guide for your
call server for a detailed power cord description.
Attach the female end of the power cord to the AC power receptacle
b.
on the left side of the Application Gateway back panel. See
on page
22. Plug the male end of the AC power cord into the AC power
source (wall outlet).
Power up the Application Gateway. (Do not insert the CD-ROM yet.)
5
Open the bezel door
a.
i. Grasp the tab at each end of the hinged bezel door.
ii. Gently pull the tabs out and down to open the hinged bezel door.
Chapter 3
Hardware Installation and Initial Configuration
Connecting and Powering up the Application Gateway
(Figure 13 on page
Application Gateway Hardware Installation Guide
24) to access the Power switch:
Figure 11
23

Advertisement

Table of Contents
loading

Table of Contents