Use the following procedure to ensure that the memory upgrade was
successful.
To verify a successful memory upgrade:
When upgrading to 1 GByte, the system responses indicate "1 GB" or
"1024 MB" instead of "512 MB".
Connect a standard serial interface (straight-through) cable to the
maintenance terminal and to the serial port on the back (not the front) of
the Application Gateway.
Using a terminal software program, such as Microsoft Windows
HyperTerminal, configure the terminal type of the maintenance terminal
serial port to "auto detect" terminal type.
Connect the power cable to the Application Gateway.
Press the power switch, the left-most button on the front of the

Application Gateway.

The following should appear on the maintenance terminal screen:
AMIBIOS (C)2001 American Megatrends Inc.
Copyright 1996-2001 Intel Corporation
TR440BXA.86B.0042.P15.0107200951
Intel(R) Pentium(R)III processor, 700MHz
512MB OK
Hit <F2> if you want to run SETUP
Optional. To do a more detailed memory test:
Press the F2 button.
a.
Navigate to the "Boot" menu.
b.
Disable the Quickstart option.
c.
Appendix A
Verifying a Successful Memory Upgrade
Application Gateway Administration Guide
Upgrading Memory
39