Resetting The Pump To Factory Defaults - Pentair Pool Products STA-RITE IntelliPro 4x160 Installation And User Manual

Four speed variable centrifugal pump with integral trap
Table of Contents

Advertisement

Setting the pump communication address
5. Change the active address by pressing the appropriate Speed button (Speed 1, Speed 2, Speed 3
or Speed 4) while the Alarm LED is flashing.
6. Once the desired address has been selected, press and hold the Start and Stop buttons again. The
Alarm LED will stop flashing and the Speed LED for the previously selected run speed will
illuminate.
7. Release the Start and Stop buttons.

Resetting the pump to factory defaults

The IntelliPro pump can be reset to the factory default settings. All previously adjusted pump speeds that were
saved will be erased.
To reset the pump to the factory default settings:
1. Ensure that the pump is powered on and the green power LED is on.
2. Press the Stop button to stop the pump.
3. Press and hold all of the four Speed buttons simultaneously for three seconds. Power off the drive
and reenergize. The default settings will be in effect.