Drive Assembly Removal and Installation
3. Remove the three Phillips head screws securing the drive to the motor assembly as shown.
CAUTION: TO AVOID ELECTRICAL HAZARD, DO NOT REMOVE THE FOUR
TAMPER PROOF BITS FROM THE MOTOR ASSEMBLY
4. Lift up the drive assembly and remove it from the motor adapter located on top of the motor assembly.
Note: Be careful not to remove the gasket between the drive and motor, it is critical in keeping
moisture out of the drive and motor. Replace the gasket if damaged. Do not reassemble with a
damaged or missing gasket.
To install the IntelliPro drive assembly onto the motor assembly:
1. Make sure all electrical breakers and switches are turned off before installing the drive.
2. Be sure that the gasket between the drive and motor is in place. It is critical in keeping moisture out of
the drive and motor. Replace the gasket if damaged. Do not reassemble with a damaged or missing
gasket.
3. Verify that the three (3) orange motor post caps are in position before placing the drive on the motor
assembly.
4. Align the drive assembly with the motor adapter and seat the drive on the motor assembly.
5. Secure and tighten the drive assembly with the three Phillips head screws.
Phillips head screw
IntelliPro Installation and User's Guide
(Continued)
Phillips head screws
Do not remove
these screws
Adapter connector
and gasket
Orange motor post
caps (QTY. 3)