Startup For Winterized Equipment
1. Remove any temporary weather protection placed around system.
2. Follow the filter manufacturer's instructions for reactivation of the filter.
3. Inspect all electrical wiring for damage or deterioration over the shutdown period. Have a qualified
serviceman repair wiring as needed.
4. Inspect and tighten all watertight connections.
5. Open all valves in suction and return piping.
6. Remove any winterizing plugs in piping system.
7. Drain all antifreeze from system.
8. Close all drain valves and replace all drain plugs in piping system.
9. Prime pump according to instructions on Page x.
Pump Service
•
Pump should only be serviced by qualified personnel.
•
For best results, use only genuine Sta-Rite factory parts.
•
Be sure to prime pump (page 19) before starting.
CAUTION - Before removing clamp or trap cover:
1. STOP PUMP before proceeding.
2. DISCONNECT THE COMMUNICATIONS CABLE from the pump.
3. CLOSE GATE VALVES in suction and discharge pipes.
4. RELEASE ALL PRESSURE from pump and piping system.
5. NEVER tighten or loosen clamp while pump is operating!
WARNING - To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before working
on pump or motor. No lubrication or regular maintenance is needed beyond reasonable care and periodic
cleaning of the strainer basket.
IntelliPro Installation and User's Guide
21