Wiring the IntelliPro

To connect the IntelliPro to an AC power source:
1. Make sure all electrical breakers and switches are turned off before wiring motor.
2. Make sure that the wiring voltage is 230 VAC.
3. Use #12 AWG for wire runs up to 100 feet and #10 AWG for lengths longer than 100 feet. When in
doubt use a heavier gauge (larger diameter) wire. Heavier gauge will allow the motor to run cooler and
more efficient.
4. Make sure all electrical connections are clean and tight.
5. Cut the wires to the appropriate length so they do not overlap or touch when connected.
6. Permanently ground the motor using the green ground wire, as shown below. Use the correct wire size
and type specified by National Electrical Code. Make sure the ground wire is connected to an electrical
service ground.
7. Bond the motor to the pool structure in accordance with the National Electrical Code. Use a solid
No. 8 AWG or larger copper conductor (No. 6 or larger in Canada). Run a wire from the external bonding
lug to the pool bonding structure, as shown below.
8. Permanently connect the pump to a non-GFCI circuit breaker, two-pole timer or relay in an automation
controller. Be sure that no other lights or appliances are on the same circuit.
NOTE: The IntelliPro will not function properly when powered from a GFCI device.
NOTE: When the IntelliPro is started and stopped by removing power with a relay or timer,
a two-pole device should be used to apply and remove power to both of the red power leads.
9. For wiring pinouts for the communications port, see page 12.
GROUND WIRE
(GREEN)
IntelliPro wiring harness
Red = Hot
Red = Hot
Green/yellow stripe = Ground
BONDING LUG
IntelliPro Installation and User's Guide
7