6.8 Parameters for direct control of the dimming actuator

The parameter Control channel C1 directly determines whether the input functions as a
direct control for C1 or purely as a KNX binary input.
Channel I1 is configured for direct control of the actuator in the ETS default setting.
A button connected to I1 will therefore have a direct internal effect on channel C1.
If the operation of the dimmer requires 2 buttons (dimming brighter/darker), i.e. 2
inputs, then I2 will be automatically configured for direct control.
If the operation of the dimmer requires only one button (one button operation), then
input I2 is freely available as a KNX binary input.
If an input is configured for direct control, it has no bus connection, i.e. no
communication objects.
Flush-mounted dimming actuator DU 1