Chapter 4
[UA-90]to[UA-94][Ub-01]to[Ub-05]
[UC-01]
MOP keypad setting
Code/Name
UA-90
Waiting time for turning off
the display(MOP)
UA-91
Initial
display
selection
(MOP)
UA-92
Enable auto-return to the
initial display (MOP)
UA-93
Enable frequency changes
through monitor
display(MOP)
UA-94
Enable multi-speed
frequency changes through
monitor display (MOP)
・Above parameters set the behavior of the MOP keypad.
Initialize
Code/Name
00(Disable)/
01(Error history clear)/
02(Data initialize)/
03(Error history clear & Data
initialize)/
04(Error history clear & Data
initialize & EzSQ clear)/
Ub-01
05(All data except terminal
Initialize
configuration)/
mode selection
06(All data except
communication
configuration)
07(All data except terminal &
communication
configuration)/
08(EzSQ only)
Ub-02
00(JP)/01(EU)/
Initialize
02(US)/03(CHN)
data selection
00(Very Low Duty)/
Ub-03
01(Low Duty)/
Load type selection
02(Normal Duty)
Ub-05
00(Disable)/
Enable
01(Execute initialization)
initialization
・How to initialize; at first select the initial mode at [Ub-01], next,
when [Ub-05] is set to 1, initialize process is start.
・Once setting the load type selection [Ub-03], the inverter load
rating will be changed instantaneously.
・SH1-03410-H(SH1-1600H) ~ SH1-04810-H(SH1-2200H) support
only normal duty(ND) and low duty (LD).
Factory setting
Code/Name
UC-01
(-)
Initial
Range (unit)
value
0 to 60(min)
(Select from d----,
dA-01
F---- parameters)
00(Disable)/
00
01(Enable)
00(Disable)/
00
01(Enable)
00(Disable)/
00
01(Enable)
Initial
Range (unit)
value
00
00(JPN)
01(EU)
02(USA)
03(CHN)
02
00
Range (unit)
Initial value
(Do not change)
(00)
For parameter configuration
Trace function
Code/Name
Ud-01
Trace function enable
Ud-02
Trace start *1)
0
Ud-03
Number of trace data setting
Ud-04
Number of trace signals setting
Ud-10
Trace data 0 selection
Ud-11
Trace data 1 selection
Ud-12
Trace data 2 selection
Ud-13
Trace data 3 selection
Ud-14
Trace data 4 selection
Ud-15
Trace data 5 selection
Ud-16
Trace data 6 selection
Ud-17
Trace data 7 selection
Ud-20
Trace signal 0 input/output
selection
Ud-21
Trace signal 0 input terminal
selection
Ud-22
Trace signal 0 output terminal
selection
Ud-23
Trace signal 1 input/output
selection
Ud-24
Trace signal 1 input terminal
selection
Ud-25
Trace signal 1 output terminal
selection
Ud-26
Trace signal 2 input/output
selection
Ud-27
Trace signal 2 input terminal
selection
Ud-28
Trace signal 2 output terminal
selection
Ud-29
Trace signal 3 input/output
selection
Ud-30
Trace signal 3 input terminal
selection
Ud-31
Trace signal 3 output terminal
selection
Ud-32
Trace signal 4 input/output
selection
Ud-33
Trace signal 4 input terminal
selection
Ud-34
Trace signal 4 output terminal
selection
Ud-35
Trace signal 5 input/output
selection
Ud-36
Trace signal 5 input terminal
selection
Ud-37
Trace signal 5 output terminal
selection
*1) Trace start is also possible from ON of input terminal 108[DTR] or
from ProDriveNext. And while the inverter is in trace function, the
output terminal 079[TRA] turns ON.
For more information, contact your supplier or local Hitachi inverter
sales office.
4-56
[Ud-01] to [Ud-37]
Initial
Range (unit)
value
00(Disable)/01(
00
Enable)
00(Stop)/01(Sta
00
rt)
0 to 8
1
0 to 8
1
dA-01
dA-01
dA-01
(parameters of
dA-01
the d**** and
dA-01
F**** mode)
dA-01
dA-01
dA-01
00(Input:[Ud-21
])/01(Output:
00
[Ud-22])
Same as [CA-01]
001
Same as [CC-01]
001
00(Input:[Ud-24
])/01(Output:
00
[Ud-25])
Same as [CA-01]
001
Same as [CC-01]
001
00(Input:[Ud-27
])/01(Output:
00
[Ud-28])
Same as [CA-01]
001
Same as [CC-01]
001
00(Input:[Ud-30
])/01(Output:
00
[Ud-31])
Same as [CA-01]
001
Same as [CC-01]
001
00(Input:[Ud-33
])/01(Output:
00
[Ud-34])
Same as [CA-01]
001
Same as [CC-01]
001
00(Input:[Ud-36
])/01(Output:
00
[Ud-37])
Same as [CA-01]
001
Same as [CC-01]
001