Hitachi SH1 Series Basic Manual page 100

Hide thumbs Also See for SH1 Series:
Table of Contents

Advertisement

Chapter 4
[Ud-38] to [Ud-60]
Trace function
Code/Name
Ud-38
Trace signal 6
input/output selection
Ud-39
Trace signal 6 input
terminal selection
Ud-40
Trace signal 6 output
terminal selection
Ud-41
Trace signal 7
input/output selection
Ud-42
Trace signal 7 input
terminal selection
Ud-43
Trace signal 7 output
terminal selection
Ud-50
Trace trigger 1
selection
Ud-51
Trigger 1 activation
selection at trace data trigger
Ud-52
Trigger 1 level
setting at trace data trigger
Ud-53
Trigger 1 activation
selection at trace signal
trigger
Ud-54
Trace trigger 2
selection
Ud-55
Trigger 2 activation
selection at trace data trigger
Ud-56
Trigger 2 level
setting at trace data trigger
Ud-57
Trigger 2 activation
selection at trace signal
trigger
Ud-58
Trigger condition
selection
Ud-59
Trigger point setting
Ud-60
Sampling time setting
・For more information, contact your supplier or local Hitachi
inverter sales office.
Initial
Range (unit)
value
00 (Input: [Ud-39])/
01 (Output: [Ud-40])
Similar to [CA-01]
001
Similar to [CC-01]
001
00 (Input: [Ud-42])/
01 (Output: [Ud-43])
Similar to [CA-01]
001
Similar to [CC-01]
001
00(Trip)/01(Data 0)/
02(Data 1)/03(Data 2)/
04(Data 3)/05(Data 4)/
06(Data 5)/07(Data 6)/
08(Data 7)/
09(Signal 0)/10(Signal 1)/
11(Signal 2)/12(Signal 3)/
13(Signal 4)/14(Signal 5)/
15(Signal 6)/16(Signal 7)
00(Action at rising above
the trigger level)/
01(Action at falling below
the trigger level)
0 to 100(%)
00(Action by signal on)/
01(Action by signal off)
00(Trip)/01(Data 0)/
02(Data 1)/03(Data 2)/
04(Data 3)/05(Data 4)/
06(Data 5)/07(Data 6)/
08(Data 7)/
09(Signal 0)/10(Signal 1)/
11(Signal 2)/12(Signal 3)/
13(Signal 4)/14(Signal 5)/
15(Signal 6)/16(Signal 7)
00(Action at rising above
the trigger level)/
01(Action at falling below
the trigger level)
0 to 100(%)
00(Action by signal on)/
01(Action by signal off)
00(At trace trigger 1
activation)/
01(At trace trigger 2
activation)/
02(Trigger-1 OR trigger-2
activation)/
03(Trigger-1 AND trigger-2
activation)
0 to 100(%)
01(0.2ms)/02(0.5ms)/
03(1ms)/04(2ms)/
05(5ms)/06(10ms)/
07(50ms)/08(100ms)/
09(500ms)/10(1000ms)
For parameter configuration
EzSQ
Code/Name
UE-01
00
EzSQ execution cycle
UE-02
EzSQ enable setting
EzSQ creates a program with inverter setup software
ProdriveNext. To operate the EzSQ function, it is necessary to
00
download the program into the inverter.
Code/Name
UE-10
EzSQ User parameter U(00)
UE-11
EzSQ User parameter U(01)
UE-12
EzSQ User parameter U(02)
UE-13
EzSQ User parameter U(03)
UE-14
EzSQ User parameter U(04)
00
UE-15
EzSQ User parameter U(05)
UE-16
EzSQ User parameter U(06)
UE-17
EzSQ User parameter U(07)
UE-18
EzSQ User parameter U(08)
UE-19
EzSQ User parameter U(09)
00
UE-20
EzSQ User parameter U(10)
UE-2
1
EzSQ User parameter U(11)
0
UE-22
EzSQ User parameter U(12)
UE-23
EzSQ User parameter U(13)
00
UE-24
EzSQ User parameter U(14)
UE-25
EzSQ User parameter U(15)
UE-26
EzSQ User parameter U(16)
UE-27
EzSQ User parameter U(17)
UE-28
EzSQ User parameter U(18)
00
UE-29
EzSQ User parameter U(19)
UE-30
EzSQ User parameter U(20)
UE-31
EzSQ User parameter U(21)
UE-32
EzSQ User parameter U(22)
UE-33
EzSQ User parameter U(23)
00
UE-34
EzSQ User parameter U(24)
UE-35
EzSQ User parameter U(25)
0
UE-36
EzSQ User parameter U(26)
UE-37
EzSQ User parameter U(27)
00
UE-38
EzSQ User parameter U(28)
UE-39
EzSQ User parameter U(29)
UE-40
EzSQ User parameter U(30)
UE-41
EzSQ User parameter U(31)
00
UE-42
EzSQ User parameter U(32)
UE-43
EzSQ User parameter U(33)
UE-44
EzSQ User parameter U(34)
UE-45
EzSQ User parameter U(35)
0
UE-46
EzSQ User parameter U(36)
UE-47
EzSQ User parameter U(37)
03
UE-48
EzSQ User parameter U(38)
4-57
[UE-01] to [UE-48]
Range (unit)
00(1ms)/
01(2ms: SJ700/L700
compatible)
00(Disable)/
01([PRG] terminal)/
02(Always enabled)
Range (unit)
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
Initial
value
00
00
Initial
value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Hide quick links: