Chapter 4
[Hd202] to [Hd237]
2nd motor When Intelligent Input terminal 024[SET] is enabled.
Code/Name
Hd202
Sync. Motor capacity setting, 2nd-motor
Hd203
Sync. Motor number of poles setting,
2nd-motor
Hd204 Sync. Base frequency setting,
2nd-motor
Hd205 Sync. Maximum frequency setting,
2nd-motor
Hd206 Sync. Motor rated voltage,
2nd-motor
Hd208 Sync. Motor rated current,
2nd-motor
Hd210 Sync. Motor constant R,
2nd-motor
Hd212 Sync. Motor constant Ld,
2nd-motor
Hd214 Sync. Motor constant Lq,
2nd-motor
Hd216 Sync. Motor constant Ke,
2nd-motor
Hd218 Sync. Motor constant J,
2nd-motor
2nd motor When Intelligent Input terminal 024[SET] is enabled.
Code/Name
Hd230 Minimum frequency adjustment for
Sync.M, 2nd-motor
Hd231 No-Load current for Sync.M,
2nd-motor
Hd232 Starting method for Sync.M,
2nd-motor
Hd233 IMPE 0V wait number for Sync.M,
2nd-motor
Hd234 IMPE detect wait number for Sync.M,
2nd-motor
Hd235 IMPE detect number for Sync.M,
2nd-motor
Hd236 IMPE voltage gain for Sync.M,
2nd-motor
Hd237 IMPE Mg-pole position offset,
2nd-motor
[oA-10] to [oA-33][ob-01] to [ob-04]
■Parameter mode (o code)
・"o" parameters are displayed by the [UA-22] = 01. This
Range
Initial
configuration is not necessary except when option is used.
(unit)
value
・The implementation of the following parameters might differ
Same as Hd102
depending on the type of option being used.
Same as Hd103
Optional cassette error operation
Same as Hd104
oA-10
Same as Hd105
an option error (SLOT-1)
Same as Hd106
oA-11
Watch Dog Timer (SLOT-1)
Same as Hd108
oA-12
Same as Hd110
communication error (SLOT-1)
Same as Hd112
oA-13
Same as Hd114
selection at start up (SLOT-1)
Same as Hd116
oA-20
an option error (SLOT-2)
Same as Hd118
oA-21
Watch Dog Timer (SLOT-2)
Range
Initial
(unit)
value
oA-22
Same as Hd130
communication error (SLOT-2)
Same as Hd131
oA-23
Same as Hd132
selection at start up (SLOT-2)
oA-30
Same as Hd133
an option error (SLOT-3)
Same as Hd134
oA-31
Watch Dog Timer (SLOT-3)
Same as Hd135
Same as Hd136
oA-32
communication error (SLOT-3)
Same as Hd137
oA-33
selection at start up (SLOT-3)
P1-FB Encoder Feedback Option setting
ob-01
setting (option)
ob-02
sequence selection (option)
ob-03
numerator (option)
ob-04
denominator (option)
4-48
For parameter configuration
For more information, please contact your supplier or
local Hitachi inverter sales office.
Code/Name
Operation selection at
Communication
Action selection at a
RUN command
Operation selection at
Communication
Action selection at a
RUN command
Operation selection at
Communication
Action selection at a
RUN command
In P1-CCL CC-Link communication option, there are no
dedicated parameters other than the above parameters.
For more information, please contact your supplier or
local Hitachi inverter sales office.
Code/Name
Encoder constant
32 to 65535(pls)
00(Phase-A Lead)/
Encoder phase
01(Phase-B Lead)
Motor gear ratio
1 to 10000
Motor gear ratio
1 to 10000
Above parameters set the main encoder input and the motor
gear ratio involved in the encoder feedback for the P1-FB.
Initial
Range (unit)
value
00(Error)/
01((Ignore error
00
(keep running))
0.00 to 100.00(s)
1.00
00(Error)/
01(Trip after Deceleration
stop)/02(Ignore)/
01
03(Free run stop)/
04(Deceleration stop)
00(Disable)/
00
01(Enable)
00(Error)/
01((Ignore error
00
(keep running))
0.00 to 100.00(s)
1.00
00(Error)/
01(Trip after Deceleration
stop)/
01
02(Ignore)/
03(Free run stop)/
04(Deceleration stop)
00(Disable)/
00
01(Enable)
00(Error)/
01((Ignore error
00
(keep running))
0.00 to 100.00(s)
1.00
00(Error)/
01(Trip after Deceleration
stop)/02(Ignore)/
01
03(Free run stop)/
04(Deceleration stop)
00(Disable)/
00
01(Enable)
Initial
Range (unit)
value
1024
0
1
1