Hitachi SH1 Series Basic Manual page 77

Hide thumbs Also See for SH1 Series:
Table of Contents

Advertisement

Chapter 4
[CA-60] to [CA-84]
[FUP] / [FDN] operations
Code/Name
CA-60
FUP/FDN overwrite
target selection
CA-61
FUP/FDN data save
enable
CA-62
FUP/FDN UDC selection
CA-64
Acceleration time
setting for FUP/FDN function
CA-66
Deceleration time
setting for FUP/FDN function
・[CA-60] sets as operation target the frequency reference or the PID
target value for 020[FUP]/021[FDN].
・[CA-61] sets whether the modified values of [FUP] / [FDN] should be
saved or not in the inverter non-volatile memory.
・[CA-62] selects the frequency reference when input terminal 022[UDC]
is ON.
・If [FUP]/[FDN] is turn ON, in the case the frequency reference is
changed you can set the acceleration and deceleration time
[CA-64][CA-66].
[F-OP] Speed/Operation change
Code/Name
01(Terminal[Ai1])/02(Terminal[Ai2])/
03(Terminal[Ai3])/04(Terminal[Ai4])/
05(Terminal[Ai5])/06(Terminal[Ai1])/
CA-70
Speed
07(Parameter Setting)/
08(RS485)/09(Option-1)/
reference source
10(Option-2)/11(Option-3)/
selection when
12(Pulse train input(internal))/
[F-OP] is active
13(Pulse train input(option))/
14(Program function)/
15(PID calc.)/16(MOP( VR))
CA-71
RUN
00([FW]/[RV] terminal)/
01(3-wire)/02(Keypad's RUN key)/
command source
03(RS485)/04(Option-1)/
selection when
05(Option-2)/06(Option-3)
[F-OP] is active
・If input terminal 023[F-OP] is ON, the above settings are carried out.
Reset terminal [RS]
Code/Name
00(Always enabled (Trip release at
turn-ON))/
01(Always enabled (Trip release at
CA-72
turn-OFF))/
Reset mode
02(Only enable in trip status (Trip release
selection
at turn-ON))/
03(Only enable in trip status (Trip release
at turn-OFF))
・Normally, frequency, terminals and etc. Outputs are OFF when reset
terminal is ON. It is also possible to enable only trip reset.
Main encoder input
Code/Name
CA-81
Encoder constant setting
CA-82
Encoder phase
sequence selection
CA-83
Motor gear ratio
numerator
CA-84
Motor gear ratio
denominator
・Above parameters set the motor gear ratio involved in the encoder
feedback to input terminal [A]/[B].
Initial
Range (unit)
value
00(Speed reference)
01(PID1 Set point)
00(No save)/
01(Save)
00(0Hz)/
01(Saved data)
30.00
0.00 to 3600.00(s)
30.00
Initial
Range (unit)
value
Range (unit)
(For input terminals [A]/[B])
Range (unit)
Initial value
32 to 65535(pulse)
1024
00(Phase-A Lead)/
01(Phase-B Lead)
1 to 10000
1 to 10000
For parameter configuration
Pulse train input terminal [A][B]
Code/Name
CA-90
00
Pulse train input, target
function selection
00
CA-91
00
Pulse train input mode
selection
CA-92
Pulse train frequency
scale
CA-93
Pulse train frequency
filter time constant
CA-94
Pulse train frequency
bias value
CA-95
Pulse train
upper frequency
detection level
CA-96
Pulse train
lower frequency
detection level
・When [CA-90] is other than 00, the input terminals [A]/[B] become
pulse train input terminals.
01
Assign the input terminal function 103[PLA]/104[PLB] to terminals
[A]/[B] to perform pulse train input frequency reference, vector
control with encoder feedback or absolute position control. The pulse
train count method follows the setting of [CA-91].
Pulse train input counter
00
Code/Name
CA-97
Pulse counter compare match
output ON value
Initial
CA-98
Pulse counter compare match
value
output OFF value
CA-99
Pulse counter maximum value
00
・Set 044[PCMP] to output the compare results of the pulse train
counters of functions 103[PLA]/104[PLB].
・Turning 097[PCC] terminal in ON state resets the counter.
Internal counter
Max. count value
[CA-99]
OFF level [CA-98]
ON level [CA-97]
0
00
[PLA] input
[PCC] input
1
[PCMP] output
1
4-34
[CA-90] to [CA-99]
Range (unit)
00(Disable)/
01(Reference)/
02(Speed feedback)/
03(Pulse count)
00(90 degrees shift pulse
train)/
01(Forward/Reverse pulse
train and direction signal)/
02(Forward pulse train and
reverse pulse train)
0.05 to 32.00(kHz)
0.01 to 2.00(s)
-100.0 to 100.0(%)
0.0 to 100.0(%)
0.0 to 100.0(%)
Range
(unit)
0 to 65535
0 to 65535
0 to 65535
Initial
value
00
00
25.00
0.10
0.0
100.0
0.0
Initial
value
0
0
65535

Hide quick links: