Chapter 4
[HC101] to [HC115]
Automatic torque boost adjustment
Code/Name
HC101
Automatic torque boost
voltage compensation gain, 1st-motor
HC102
Automatic torque boost slip
compensation gain, 1st-motor
・These parameters are adjusted when the automatic
torque boost control function is selected in [AA121].
For more information, please contact your supplier
or local Hitachi inverter sales office.
Vector control start adjustment
Code/Name
HC110
Zero speed range limit,
1st-motor(IM-0Hz-SLV)
HC111
Boost value at start,
1st-motor (IM-SLV,IM-CLV)
HC112
Boost value at start,
1st-motor (IM-0Hz-SLV)
・When [AA121] is sensorless vector control or 0Hz-range
sensorless vector control, start boost is possible.
Secondary resistor compensation function
Code/Name
HC113
Secondary resistance
(R2) correction, 1st-motor
・When the vector control (with encoder/ sensorless/0Hz)
is being used and the temperature of the motor can be
sensed, the inverter is capable of reducing the speed
variations due to temperature changes.
・If use this function, use a thermistor PB-41E from
SHIBAURA ELECTRONICS CO., LTD.
And also, it is necessary to set [Cb-40] to 02 (NTC).
Reverse run protection function
Code/Name
HC114
Direction reversal
protection, 1st-motor
・This function is to prevent the change of direction of the
output in a low frequency range for vector control such
as (SLV/0Hz-SLV/CLV).
Torque reference value conversion method
Code/Name
HC115
Torque conversion
method selection, 1st-motor *1)
*1) [HC115]/[HC215] are parameters added to Ver2.02 or
later.
• Select the 100% reference value of the torque related
setting parameter. (Setting 01 is the same method as
the SJ700 series.)
For more information, please contact your supplier
or local Hitachi inverter sales office.
Initial
Range (unit)
value
0 to 255(%)
100
0 to 255(%)
100
Range (unit)
Initial value
0 to 100(%)
80
0 to 50(%)
0
0 to 50(%)
10
Initial
Range (unit)
value
00(Disable)/
00
01(Enable)
Initial
Range (unit)
value
00(Disable)/
00
01(Enable)
Initial
Range (unit)
value
00(Torque)/
00
01(Current)
For parameter configuration
Torque reference value conversion method
Code/Name
HC120
Torque current reference filter
time constant, 1st-motor
HC121
Speed feedforward
compensation gain, 1st-motor
HC137
Flux settling level, 1st-motor
HC140
Forcing level, 1st-motor *2)
HC141
Modulation threshold 1,
1st-motor *2)
HC142
Modulation threshold 2,
1st-motor *2)
・[HC120] to [HC142] are effective when the control mode is
sensorless vector control(IM), Zero-Hz-range sensorless vector
control (IM) or Vector control with encoder (IM).
・[HC120] sets a filter for torque command.
・[HC121] adjusts the compensation of feedforward control.
・[HC137] adjusts the magnetic flux establishment level at start
up. If this is set to a small, the waiting time until acceleration
starts can be shortened, but the startup operation may become
unstable.
・[HC140] adjusts the output current level during pre-excitation.
The basis current value is as follows depending on the control
mode.
08:Sensorless vector control (IM)
09:Vector control with encoder(IM)
10:Zero-Hz-range sensorless vector
control
・[HC141]/[HC142] adjust the upper limit of the inverter output
voltage level. By increasing these parameters the output
current may be reduced, and the operation may become
unstable.
Be sure to set the same value for [HC141] and [HC142].
2nd motor When Intelligent Input terminal 024[SET] is enabled.
Code/Name
HC201
Automatic torque boost voltage
compensation gain, 2nd-motor
HC202
Automatic torque boost slip
compensation gain, 2nd-motor
HC210
Zero speed range limit,
2nd-motor(IM-0Hz-SLV)
HC211
Boost value at start,
2nd-motor(IM-SLV,IM-CLV)
HC212
Boost value at start,
2nd-motor(IM-0Hz-SLV)
HC213
Secondary resistor (R2) compensation
enable, 2nd-motor
HC214
Direction reversal protection,
2nd-motor
HC215
Torque conversion method selection,
2nd-motor
HC220
Torque current reference filter time
constant, 2nd-motor
HC221
Speed feedforward compensation gain,
2nd-motor
HC237
Flux settling level, 2nd-motor
HC240
Forcing level, 2nd-motor *2)
HC242
Modulation threshold 2, 2nd-motor *2)
*2)[HC137]/[HC237],[HC140]/[HC240],[HC141]/[HC241],
[HC142]/[HC242] are parameters added to Ver2.03 or later.
4-46
[HC120] to [HC242]
Range (unit)
0 to 100(ms)
0 to 1000(%)
0.0 to 100.0(%)
*2)
0 to 1000(%)
0 to 133(%)
0 to 133(%)
[Hb116] Async. Motor
constant I0
[HC110] Zero speed range
limit (IM -0Hz-SLV)
Range
Initial
(unit)
value
Same as HC101
Same as HC102
Same as HC110
Same as HC111
Same as HC112
Same as HC113
Same as HC114
Same as HC115
Same as HC120
Same as HC121
Same as HC137
*2)
Same as HC140
Same as HC142
Initial
value
2
0
80.0
100
115
115