REP 4.7
Scan PBA
Removal
1.
Remove the following:
a.
Front Cover (REP 4.11).
2.
Remove two screws, then remove the scan cover.
WorkCentre 385
3.
Unplug all connectors from the scan PBA, remove one screw, then remove
the PBA.
Replacement
1.
Reinstall the components in the reverse order.
12/98
www.printcopy.info
4 - 9
REP 4.7 Scan PBA