Check Drum Menu - Xerox WorkCentre C2424DX Service Manual

Hide thumbs Also See for WorkCentre C2424DX:
Table of Contents

Advertisement

Tray 2, Tray 3, Tray 4, Lift Plate Drive (Continued)
This test raises the lift plate to verify motion and sensor operation. If the test is requested for a
525-sheet feeder that is not installed, an "Option Not Detected" message is generated.
R#
Definition
Lift Contact Time
4
(sec)
Lift Time (sec)
5
Stall Power (watts)
6

Check Drum Menu

Y-axis Encoder
Uses the sine and cosine sum data to determine the characteristics of the encoder disk and
encoder sensors.
R#
Definition
Sin Sum Data
0
Amplitude (sin sum
units)
Cosine Sum Data
1
Amplitude (cosine
sum units)
Sin Sum Data Offset
2
(sin sum units)
Cosine Sum Data
3
Offset (cosine sum
units)
Home Notch Depth
4
Ratio (none)
Home Notch Width
5
(sec)
Home Notch
6
Symmetry (none)
4-40
Typical
Value
Actions
MFG
Reports the interval from the motor start time
Only
until the required lift power starts to increase
due to the initial contact with the nudger roller
assembly.
MFG
Reports the interval from the motor start time
Only
until plate lifted is indicated.
MFG
Reports the average stall power during the
Only
overlifting interval.
Typical
Value
Actions
MFG
Reports difference between the max and min
Only
Sin Sum average amplitude values.
MFG
Reports difference between the max and min
Only
Cosine Sum average amplitude values.
MFG
Reports average of the max and min Sin Sum
Only
average amplitude values.
MFG
Reports average of the max and min Cosine
Only
Sum average amplitude values.
MFG
Reports the ratio between the notch bottom
Only
amplitude and the max amplitude value as
reflected in the Sin Sum data.
MFG
Reports the width of the Home notch at 99%
Only
full depth as reflected in the Sin Sum data.
MFG
Reports the ratio of the Home notch width
Only
sections as bisected by a vertical from the
notch min as reflected in the Sin Sum data.
WorkCentre C2424 Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre c2424

Table of Contents