16 Keyboard dialing
Keyboard dialing exceptions
Table 1contains exceptions to normal KBD operating procedures
including suggested corrective actions. (The Break key refers to the
Control-Z sequence.
Table 1 KBD operation exceptions
Problem
Attempt to activate
unassigned feature
failed, or call attempt
failed.
Incoming or outgoing
call failed because of
communications
incompatibility.
Dialing aborted by
pressing Break key
(Control Z).
User pressed CR
only when prompted
for number input.
User input errors
committed.
DN input times-out,
or RAG activation
times-out.
RAG recall timeout
occurs.
Extended Hayes keyboard dialing
User input characteristics
Hayes Keyboard Dialing input must conform to the following
characteristics:
•
555-4001-110 Standard 09.03 July, 2002
Each command line must begin with the letters AT and end with a
carriage return. If the MADO is in autobaud mode, AT is used to set
System response
NO SYSTEM
RESPONSE.
RESELECT:
INCOMPATIBLE
COMMUNICATIONS
PARAMETER. CALL
RELEASED.
ABORTED
ABORTED
INVALID
COMMAND/ENTRY.
REENTER:
CALL RELEASED
RING AGAIN
CANCELLED
Corrective action
Key in a new
selection from the
appropriate menu.
Reenter appropriate
selection or proper
DN.
No corrective action
necessary. Main
Menu redisplays.
No corrective action
necessary. Main
Menu redisplays.
Reenter appropriate
selection or proper
DN.
No corrective action
necessary. Main
Menu redisplays.
No corrective action
necessary. Main
Menu redisplays.