Loop engineering

The M2000 Digital Telephones operate at their full potential through
twisted-pair wiring where the maximum permissible loop length is less
than 3000 ft (915 m) of 24 AWG (0.5 mm) standard twisted wire with no
bridge taps.
The maximum loop length assumes no under-carpet cable, the
maximum allowable cable must be reduced using the following
equation:
LM = (14 - (UC x UL)) / 14
where
LM = loop length in ft (km)
UC = length of the under-carpet cable in ft (km)
UL = loss of the under-carpet cable in dB/ft (dB/km) at 256 kHz

Data characteristics

The MADO communicates with the Data Terminal Equipment (DTE)
using the characteristics listed in the following table;
Table 2 MADO Data characteristics
Characteristic
Data type
Synchronization
Number of bits
Parity
Data rate
Stop bits
555-4001-110 Standard 09.03 July, 2002
Specification
ASCII (ANSI standard
X3.4-1977)
Asynchronous
7 bits plus parity or 8 bits, no
parity
None, odd, or even
110, 150, 300, 600, 1200, 2400,
4800, or 19200 bits per second
1 bit for all speeds