Nortel M2000 Reference Manual page 60

Meridian sl-100
Hide thumbs Also See for M2000:
Table of Contents

Advertisement

5
Dial the 6-digit ID code.
Response: The system provides dial tone for a duplicate ID
code and disconnects the call. The system provides
confirmation tone for successful authorization. The system takes
the LEN associated with the set and the LEN of the associated
data device out of service by setting the line states to INB. The
system moves the set's datafill from the old LEN to a virtual LEN.
Note: Remember this number. It is used again in Procedure
7.
6
Unplug the telephone set.
7
Take the set to its new location.
Task is complete.
Procedure 9 ARS in process
CAUTION
Telephone set damage
If the set is not plugged into the correct jack, one of
the following errors could occur:
1. If the Jack belongs to a non-IVD line card and an
IVD set is plugged into this jack, damage to the digital
set, line card , or both may occur.
2. If the jack does belong to an IVD line card and the
line already contains datafill, the user may not
receive dial tone if the jack is out of service or may
receive normal dial tone if the jack is in service.
3. Plug the telephone set only into an IVD line card
(NT8X47BA).
1
Plug the set into any properly equipped jack.
Response: The system recognizes the set and datafills the new
LEN with temporary datafill.
2
Wait 30 seconds before proceeding to Step 3.
3
Lift the handset of the telephone set.
Note: If no dial tone is received, release the call, and try
again. If dial tone is still not received, contact the system
administrator.
Meridian SL-100 M2000 Digital Telephone Reference Manual
Testing and maintenance 15