8 Testing and maintenance
3
Table XLANAME
Table XLANAME (Translation Name) controls the addition and deletion
of translators to the IBN Translations table.
Each translator is assigned a 1-8 character name plus the default data.
This default data is used for that translator name whenever an access
code is not specified in table IBNXLA.
Table 1 describes the fields to enter. For more information on table
XLANAME, refer to the Defense Switched Network Customer Data
555-4001-110 Standard 09.03 July, 2002
repeated attempts to set up the MADO Self Test fail, contact
service personnel.
If confirmation tone is received and MADO TEST IS COMPLETE
appears on the DTE screen, the MADO circuit board is in
working order. If there is a data communications failure, the DTE,
RS-232-C interface, or cable could be faulty.
If reorder tone is received for 5 seconds and MADO TEST IS
COMPLETE appears on the DTE screen, the MADO Self Test
failed. The power source may be disconnected. If the power
source is securely connected, contact service personnel to
replace the MADO circuit board.
Replace the handset.
Response: MADO Self Test completes. The test is over when
the handset is replaced, regardless of whether the test has been
completed.
Note 1: If the HOLD key is pressed during the MADO Self
Test, the test is over regardless of whether the test has been
completed.
Note 2: If the MADO Self Test has been set up, and no tone
is received within 15 seconds, reorder tone is given followed
by normal call treatment.