Figure 53. Post Diagnostic Led Location - Intel P4304XXMFEN2 Service Manual

Server chassis
Hide thumbs Also See for P4304XXMFEN2:
Table of Contents

Advertisement

Intel
®
Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
Appendix B: POST Code Diagnostic LED Decoder Table
As an aid to assist in trouble shooting a system hang that occurs during a system's Power-On Self-Test
(POST) process, the server board includes a bank of eight POST Code Diagnostic LEDs on the back
edge of the server board.
During the system boot process, Memory Reference Code (MRC) and System BIOS execute a number of
memory initialization and platform configuration processes, each of which is assigned a hex POST code
number.
As each routine is started, the given POST code number is displayed to the POST Code Diagnostic LEDs
on the back edge of the server board.
During a POST system hang, the displayed post code can be used to identify the last POST routine that
was run prior to the error occurring, helping to isolate the possible cause of the hang condition.
Each POST code is represented by eight LEDs; four Green and four Amber. The POST codes are divided
into two nibbles, an upper nibble and a lower nibble. The upper nibble bits are represented by Amber
Diagnostic LEDs #4, #5, #6, #7. The lower nibble bits are represented by Green Diagnostics LEDs #0, #1,
#2 and #3. If the bit is set in the upper and lower nibbles, the corresponding LED is lit. If the bit is clear,
the corresponding LED is off.

Figure 53. POST Diagnostic LED Location

In the following example, the BIOS sends a value of ACh to the diagnostic LED decoder. The LEDs are
decoded as follows:
Note: Diag LEDs are best read and decoded when viewing the LEDs from the back of the system.
83