Upgrading The Fixed Drive Storage To 16X2.5" Hot-Swap Drive Bay Storage - Intel P4304XXMFEN2 Service Manual

Server chassis
Hide thumbs Also See for P4304XXMFEN2:
Table of Contents

Advertisement

Intel
®
Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
2.7.8
Upgrading the Fixed Drive Storage to 16x2.5" Hot-swap Drive Bay
Storage
The server chassis can support two 8x3.5" hot-swap drive bays as an upgrade option from fixed drive
storage.
Remove the chassis side cover following instructions in section "Chassis Side Cover Removal".
Remove the front bezel following instructions in section "Removing the Front Bezel".
Note: The drive bay on the upper position should be installed first, then the second drive bay on the
lower position.
On server board side, connect the two miniSAS HD cable headers to the server board connectors
labeled as "sSATA_0-3" and "SATA_0-3", and connect the other two miniSAS HD cable headers to
the server board connectors labled as "SAS_0-3" and "SAS_4-7".
Note: The "SAS_0-3" and "SAS_4-7" are available on S2600CW2SR and S2600CWTSR.
52
Remove the fixed drive trays.
Install the drive bays.
Cable connection:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P4304xxmuxx

Table of Contents