Table 8. Post Error Beep Codes - Intel P4304XXMFEN2 Service Manual

Server chassis
Hide thumbs Also See for P4304XXMFEN2:
Table of Contents

Advertisement

Intel
®
Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
Error Code
A001
TPM device missing or not responding.
A002
TPM device failure.
A003
TPM device failed self test.
A100
BIOS ACM Error
A421
PCI component encountered a SERR error
A5A0
PCI Express component encountered a PERR error
A5A1
PCI Express component encountered an SERR error
DXE Boot Services driver: Not enough memory available to shadow a Legacy
A6A0
Option ROM.
POST Error Beep Codes
The following table lists the POST error beep codes. Prior to system video initialization, the BIOS uses
these beep codes to inform users on error conditions. The beep code is followed by a user-visible code
on the POST Progress LEDs.
Beeps
Error Message
1
USB device action
1 long
Intel® TXT security
violation
3
Memory error
3 long
CPU mismatch
and 1
error
The following Beep Codes are sounded during BIOS Recovery.
2
Recovery started
4
Recovery failed
The Integrated BMC may generate beep codes upon detection of failure conditions. Beep codes are
sounded each time the problem is discovered, such as on each power-up attempt, but are not sounded
continuously. Codes that are common across all Intel server boards and systems that use same
generation chipset are listed in the following table. Each digit in the code is represented by a sequence
of beeps whose count is equal to the digit.
94
Error Message

Table 8. POST Error Beep Codes

POST Progress Code
N/A
0xAE, 0xAF
Multiple
0xE5, 0xE6
N/A
N/A
Description
Short beep sounded whenever USB device is
discovered in POST, or inserted or removed during
runtime.
System halted because Intel
Technology detected a potential violation of system
security.
System halted because a fatal error related to the
memory was detected.
System halted because a fatal error related to the
CPU family/core/cache mismatch was detected.
Recovery boot has been initiated.
Recovery has failed. This typically happens so quickly
after recovery is initiated that it sounds like a 2-4
beep code.
Response
Minor
Minor
Minor
Major
Fatal
Minor
Fatal
Minor
®
Trusted Execution