Table 5. Mrc Fatal Error Codes - Intel P4304XXMFEN2 Service Manual

Server chassis
Hide thumbs Also See for P4304XXMFEN2:
Table of Contents

Advertisement

Intel
®
Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
POST progress codes by the accompanying memory failure beep code of 3 long beeps as identified in
Table 8.
Diagnostic LED Decoder
1 = LED On, 0 = LED Off
Checkpoint
Upper Nibble
MSB
8h
4h
2h
LED
#7
#6
#5
MRC Fatal Error Codes
E8h
1
1
1
E9h
1
1
1
EAh
1
1
1
EBh
1
1
1
EDh
1
1
1
EFh
1
1
1

Table 5. MRC Fatal Error Codes

Lower Nibble
LSB
1h
8h
4h
2h
1h
#4
#3
#2
#1
#0
0
1
0
0
0
0
1
0
0
1
0
1
0
1
0
0
1
0
1
1
0
1
1
0
1
0
1
1
1
1
No usable memory error
01h = No memory was detected from SPD read, or invalid config that
causes no operable memory.
02h = Memory DIMMs on all channels of all sockets are disabled due to
hardware memtest error.
3h = No memory installed. All channels are disabled.
Memory is locked by Intel Trusted Execution Technology and is
inaccessible
DDR3 channel training error
01h = Error on read DQ/DQS (Data/Data Strobe) init
02h = Error on Receive Enable
3h = Error on Write Leveling
04h = Error on write DQ/DQS (Data/Data Strobe
Memory test failure
01h = Software memtest failure.
02h = Hardware memtest failed.
03h = Hardware Memtest failure in Lockstep Channel mode requiring a
channel to be disabled. This is a fatal error which requires a reset and
calling MRC with a different RAS mode to retry.
DIMM configuration population error
01h = Different DIMM types (UDIMM, RDIMM, LRDIMM) are detected
installed in the system.
02h = Violation of DIMM population rules.
03h = The 3rd DIMM slot cannot be populated when QR DIMMs are
installed.
04h = UDIMMs are not supported in the 3rd DIMM slot.
05h = Unsupported DIMM Voltage.
Indicates a CLTT table structure error
Description
85

Advertisement

Table of Contents
loading

This manual is also suitable for:

P4304xxmuxx

Table of Contents