2.1 Internal Cable Routing

The system fan assembly must be removed when routing cables from front to back. All cables should
be routed using the cable channels along each chassis sidewall as shown in the following illustration.
When routing cables from front to back, none should be routed through the center of the system or in
the area between the system fans and the DIMMs slots.
1. For P4304XXMFEN2, the power cables for HDD/ODD bays should be routed through the opening
on the system fan bracket, close to the chassis side wall; for P4304XXMUXX, the power cables for
2. The front panel cable, SATA/SAS data cable(s), USB cable (to the front panel), HSBP_I2C (optional)
3. The system main power cable and CPU power cables need to be managed under the notch of the
A
CPU1/2 power cable
D
ODD drive bay power cable
G
SSD/HDD drive bay data cable
(SATA)
HDD/ODD bays should be routed under the 5
should be routed between the first system fan and the chassis sidewall.
air duct, before the air duct can be installed properly.
B
E
H
Main power cable
Front panel and USB cable
FAN_1 cable (PCIe fan)
th
system fan.
C
SSD/HDD drive bay power cable
(SAS/SATA)
F
ODD data cable
I
FAN_2 cable (CPU fan)