Appendix D: Post Code Diagnostic Led Decoder Table For S2600Cw Server Board Family; Figure 161. Post Diagnostic Led Location - Intel P4304XXMFEN2 Service Manual

Hide thumbs Also See for P4304XXMFEN2:
Table of Contents

Advertisement

Intel
®
Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
Appendix D: POST Code Diagnostic LED Decoder Table for
S2600CW Server Board Family
As an aid to assist in troubleshooting a system hang that occurs during a system's Power-On Self-Test (POST)
process, the server board includes a bank of eight POST Code Diagnostic LEDs on the back edge of the server
board.
During the system boot process, Memory Reference Code (MRC) and System BIOS execute a number of
memory initialization and platform configuration processes, each of which is assigned a hex POST code
number.
As each routine is started, the given POST code number is displayed to the POST Code Diagnostic LEDs on the
back edge of the server board.
During a POST system hang, the displayed post code can be used to identify the last POST routine that was
run prior to the error occurring, helping to isolate the possible cause of the hang condition.
Each POST code is represented by eight LEDs; four Green and four Amber. The POST codes are divided into
two nibbles, an upper nibble and a lower nibble. The upper nibble bits are represented by Amber Diagnostic
LEDs #4, #5, #6, #7. The lower nibble bits are represented by Green Diagnostics LEDs #0, #1, #2 and #3. If the
bit is set in the upper and lower nibbles, the corresponding LED is lit. If the bit is clear, the corresponding LED
is off.

Figure 161. POST Diagnostic LED Location