Upgrading The Fixed Drive Storage To 8X2.5" Pcie Ssd (Nvme) Combo Drive Bay Storage - Intel P4304XXMFEN2 Service Manual

Server chassis
Hide thumbs Also See for P4304XXMFEN2:
Table of Contents

Advertisement

Intel
®
Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
2.7.6
Upgrading the Fixed Drive Storage to 8x2.5" PCIe SSD (NVMe) Combo
Drive Bay Storage
The installation of the 8x2.5" SAS/PCIe SSD (NVMe) combo drive bay involves serveral components:
NVMe add-in card
8x2.5" SAS/PCIe SSD (NVMe) combo drive bay
NVMe cables
MiniSAS to miniSAS cables (optional)
I2C cable
1. Follow the same steps 1-4 in the previous section "Upgrading the Fixed Drive Storage to 4x3.5" or
2. Slide the 8x2.5" SAS PCIe SSD (NVMe) Combo drive bay to the upper/right drive bay position.
3. Install the NVMe add-in card to any PCIe x16 slot on the server board.
Note: The PCIe slot 5 will be PCIe x8 bandwith on S2600CW2SR and S2600CWTSR.
46
8x2.5" Hot-swap Drive Bay Storage".

Advertisement

Table of Contents
loading

This manual is also suitable for:

P4304xxmuxx

Table of Contents