Start-Up; Keys And Indicators; Allocation And Function Of Keys - Roland Double Sheet Detector I100 Manual

For double sided sensors
Table of Contents

Advertisement

B0003308 / 1.4 /
13.02.2013
6

Start-up

Pos: 25 /Doppelblech/Geräte/R1002/6 Inbetriebnahme / Bedienung/Bedienelemente und Anzeigen @ 0\mod_1184848094000_501.doc @ 4115 @
6.1

Keys and indicators

The control unit has three operating keys, which provide for easy adjustment.
Adjustment is required upon commissioning and change of material.
3
Fig. 17: Controls and indications
6.2

Allocation and function of keys

The functions of the 3 operating keys are variable, as will be shown in the lower line of the display.
Fig. 18: Indication of key allocation
Dummy I100-2.jpg
Pos: 26 /Doppelblech/Geräte/R1002/6 Inbetriebnahme / Bedienung/Belegung und Funktion der Tasten @ 0\mod_1184849242203_501.doc @ 4130 @
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R100 I100
fault
2 sheet
power
1 sheet
0 sheet
R100structure.bmp
If a function causes a fault, a fault number is indicated and the yellow
Note!
LED "FAULT" lights.
The error condition can be confirmed with the right "ENTER" key.
Otherwise the system changes to the measuring mode after approx 5
seconds. The "FAULT" LED will, however, go off only if upon a new
attempt the requested function is fault free.
If a function consists of several steps, which are not completely
executed, the system automatically changes back to the original
measuring mode after approx. 5 seconds.
Manual
for pairs of sensors
1
2
4
For example, the operator can change from the
measuring mode into the setup mode with the key
"setup".
Start-up
Description
1
LCD display
2
Operating keys
3
LEDs for condition of unit
FAULT
malfunction
POWER
power supply
4
LEDs for switch conditions
2-Sheet
1-Sheet
0-Sheet
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Double sheet detector r100

Table of Contents