B.8 H Parameters: Multi-Function Terminals
No.
(Addr.
Name
Hex)
H3-17
Terminal A2 Offset
(2F1)
H3-18
Terminal A3 Offset
(2F2)
H3-oo
Function
Setting
0
Frequency bias
1
Frequency gain
Auxiliary frequency reference 1
2
(used as a Multi-Step Speed 2)
Auxiliary frequency reference 2
3
(3rd step analog)
4
Output voltage bias
5
Accel/decel time gain
6
DC Injection Braking current
Overtorque/undertorque
7
detection level
8
Stall Prevention level during run
9
Output frequency lower limit level
B
PID feedback
C
PID setpoint
D
Frequency bias
E
Motor temperature (PTC input)
F
Not Used
16
Differential PID feedback
<1>
HAND Reference
1F
25
Secondary PI setpoint
26
Secondary PI feedback
<1> Setting 1F is "HAND Reference" in bypass controller software versions VST800298 and later. Setting 1F is "Not Used (Through Mode)" in bypass
controller software versions VST800297 and earlier.
u

H4: Analog Outputs

No.
(Addr.
Name
Hex)
Multi-Function Analog
H4-01
Output Terminal FM
(41D)
Monitor Selection
H4-02
Multi-Function Analog
(41E)
Output Terminal FM
Gain
H4-03
Multi-Function Analog
(41F)
Output Terminal FM
Bias
264
Adds an offset when the analog signal to terminal A2 is at 0 V.
Adds an offset when the analog signal to terminal A3 is at 0 V.
H3 Multi-Function Analog Input Settings
10 V = E1-04 (maximum output frequency)
0 to 10 V signal allows a setting of 0 to 100%. -10 to 0 V signal allows a setting of -100
to 0%.
10 V = E1-04 (maximum output frequency)
10 V = E1-04 (maximum output frequency)
10 V = E1-05 (motor rated voltage)
10 V = 100%
10 V = Drive rated current
10 V = Drive rated current (V/f)
10 V = Drive rated current
10 V = E1-04 (maximum output frequency)
10 V = 100%
10 V = 100%
10 V = E1-04 (maximum output frequency)
10 V = 100%
Set this value when using the terminal in the pass-through mode.
10 V = 100%
Sets the frequency reference when in HAND Mode and parameter Z1-41, HAND Speed
Reference Selection, is set to 1 (Analog).
10 V = S3-02 (maximum output frequency)
10 V = S3-02 (maximum output frequency)
LCD Display
Selects the data to be output through multi-function analog
output terminal FM.
Term FM FuncSel
Set the desired monitor parameter to the digits available in
Uo-oo.
For example, enter "103" for U1-03.
Sets the signal level at terminal FM that is equal to 100% of the
selected monitor value.
Terminal FM Gain
Sets the signal level at terminal FM that is equal to 0% of the
selected monitor value.
Terminal FM Bias
Description
Description
Description
YASKAWA SIEP YAIP1B 01B YASKAWA AC Drive – P1000 Bypass Technical Manual
Values
Page
Default: 0
Min.: -500
129
Max.: 500
Default: 0
Min.: -500
128
Max.: 500
Page
129
129
129
129
129
129
129
130
130
130
130
130
130
130
130
130
131
131
131
Values
Page
Default: 102
Range: 000 to
131
621
Default: 100.0%
Min.: -999.9
131
Max.: 999.9
Default: 0.0%
Min.: -999.9
131
Max.: 999.9