Samsung MultiXpress K4 Series Service Manual page 414

A3 mono copier
Table of Contents

Advertisement

4. Troubleshooting
► Error Code
U1–2316
U1–2317
► Error message
Fuser Unit Failure: #U1-2316.
Fuser Unit Failure: #U1-2317.
► Symptom
Temperature of the fuser changes abnormally
► Troubleshooting method
U1–2316 : Error occurs at non-contact type Thermistor
U1–2317 : Error occurs at contact type Thermistor
1) Turn the machine off. Re-install the fuser unit, then turn the machine on.
(Refer to 3.2.2. Fuser unit)
2) Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?)
3) If the problem persists, Check the following:
(Refer to 3.3.23. Fuser unit)
a) Check if the Halogen lamp
b) Check if the AC connection of the Halogen lamp is disconnected or contaminated.
c) Check if the
d) Check if the contact type
4) If the problem persists, replace the Fuser
5) If the problem persists, replace the main board(JC92–02746A) or FDB
JC44-0021A)or
SMPS(220V : JC44-00100C, 110V : JC44-00093C)
4-179
(110V : 4713–001632 / 220V : 4713–001633)
thermistat(4712-001098)
thermistor(1404–001567)
unit(220V : JC91–01163A / 110V : JC91–01164A).
is disconnected.
or Non-contact type
Copyright© 1995-2017 SAMSUNG. All rights reserved.
is broken or disconnected.
thermistor(1404–001453)
board(220V : JC44-00211A, 110V :
is broken.