Convenient Functions

Setting Temporary Holidays (Weekly)
Weekly, 2 Circuits
Temporary holidays (non-operating days) can be easily set.
Because the setting is automatically cleared after the set holiday has
passed, temporary holidays are easily set without changing other
settings, including those of the Output ON/OFF Switches.
Example: Friday and Saturday in the current week are set as
holidays (non-operating days).
The Time Switch then operates according to the ordinary
(previous) settings from the following week onward.
1. Press
HOLIDAY
RUN mode.
(The Time Switch enters holiday
setting mode.)
2. Turn OFF the bars (
positions of the days to be set as
holidays.
Bar ON: Operating day
Bar OFF: Holiday
3. Press
WRITE
After "hday" is displayed for
approximately 1 s, the Time Switch
returns to RUN mode.
Note:
• Any day in the 7-day period starting from the current day can be
set as a holiday.
The setting is automatically cleared after the set holiday has
passed.
• All ON operations are cancelled on the holiday.
• The set holidays are valid for all the output circuits.
• You must be in RUN mode to enter to holiday setting mode.
• If the current day of the week is changed, the holiday settings will
be cleared.
• Press
HOLIDAY
mode. If you do nothing for 30 s, the Time Switch will
automatically return to RUN mode.
Downloaded from
Elcodis.com
electronic components distributor
Shaded portion indicates
blinking of the indicator.
for 2 s or more in
SUN MON TUE WED THU FRI SAT
) at the
SUN MON TUE WED THU FRI SAT
to enter the setting.
for 2 s in holiday setting mode to return to RUN
Setting Temporary Holidays (Yearly)
Yearly, 2 Circuits
Yearly, 4 Circuits
Temporary* holidays (non-operating days) can be set simply by
specifying dates. The holidays will be OFF in both the weekly and
yearly programs. Because the setting is automatically cleared after
the set holiday has passed, temporary holidays are easily set without
changing other settings, including those of the Output ON/OFF
Switches.
* Annual holidays can also be set.
Example: The days from April 29 to May 7 in 2006 are set as
holidays (non-operating days). The Time Switch then
operates according to the ordinary (previous) settings
from the following year onward.
1. Press
HOLIDAY
for 2 s or more in
RUN mode. *1
(The Time Switch enters holiday
setting mode.)
2. Specify the start date of holidays
using
Y
,
M
and
D
. *2
The year is displayed in the following
order by pressing
Y
. (The year can
be set from the current year to the
next two years.)
<Example> If the current year is 2006,
the displayed year changes
as follows.
06→07→08→--→06→
If the year is set to --, the holiday
setting is executed every year.
3. Press
.
WRITE
In the same manner, specify the end
date of holidays using
Y
,
M
D
. *2
If the starting year has been set to
"--", the ending year cannot be set.
4. Press
WRITE
to enter the settings.
5. Press
HOLIDAY
for 2 s or more to return to RUN mode.
*1 If one or more programs have already been set, the display starts showing
the set programs.
WRITE
To add another program, press
displayed.
*2 Holding down the date-setting keys rapidly advances the value.
Pressing
decrements the value of the key that was last pressed.
Note:
• Any date between the current date and December 31 in the year
after the following year can be specified as a holiday.
• The setting is automatically cleared after the set holiday has
passed (unless the year is set to --).
• Repeat steps 2 to 4 to make other settings.
• Both the start and end dates of holidays must be set. The
maximum number of holidays that can be set is 16.
• You must be in RUN mode to enter to holiday setting mode.
• If the current date is changed, the holiday settings will be cleared.
• When you specify the year, be sure to set the end date so that it is
after the start date.
• Press
HOLIDAY
for 2 s in holiday setting mode to return to RUN
mode. If you do nothing for 30 s, the Time Switch will
automatically return to RUN mode.