Note: HL-5000 Limit Switches are offered with a choice of ground terminal/M5 tapping on the rear side conforming to various standards. When placing an order, add the code to the model number to indicate if ground terminal/M5 tapping on the rear side is required.
2. The above characteristics may vary depending on the model. For further details, contact your OMRON sales representative. 3. Life expectancy values are calculated at an operating temperature of 5 C to 35 C, and an operating humidity of 40% to 70%. Con- tact your OMRON sales representative for more detailed information on other operating environments.
30 0.8 mm 40 0.8 mm Note: 1. Measured with the types of the 31.5-mm arm or rod length. 2. OF and RF measured at the arm length of 75 mm for HL-5030, and 145 mm for HL-5050 (reference values). Model HL-5030 HL-5050 3.09 N...
Page 4
HL-5000 HL-5000 Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. Roller Lever HL-5000 17.5 dia. (See note 1) (See note 2) Three, M5 x 12 Note: 1.
Page 5
To change the angle of the actuator, loosen the Allen-head bolt on To change the head direction, loosen the two mounting screws. the side of the actuator lever. Then the actuator can be set at any Then the head can be changed at 90 increments in one of four angle.
Page 6
Note: Do not use wires containing silicone, otherwise a contact failure may result. Applicable Solderless Terminal The following solderless terminals are available. Do not use fork or any other type of terminals, otherwise an accidental disconnection resulting in a ground fault may result.
Page 7
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. C004-E1-9...