External I/O Safety Signal Interrupt - Delta E Series Software Instructions

Recipe setting
Table of Contents

Advertisement

伺服壓床簡易配方設定軟體操作說明
3.2.5

External I/O safety signal interrupt

1.
The external [Safety Signal] was interrupted during the pressing. [X3]→OFF
2.
The motor will stop immediately
3.
After confirming the safety control components, trigger the [Safety Signal] again. [X3]→ON
4.
Trigger the [Reset] signal. [X2]→ON
5.
The machine will abandon this pressing action, and the motors will return the spindle to the working
origin and trigger the [Waiting] signal. [Y1]→ON
6.
Stop triggering the [Reset] signal. [X2]→OFF
Restart the [Trigger] signal, and start the pressing process. [X1]→ON
7.