Cluster Interconnect Link Ports Leds - HP HPE 3PAR StoreServ 8000 Installation Manual

Table of Contents

Advertisement

Cluster Interconnect Link Ports LEDs

The controller node has two Cluster Interconnect Link ports and each includes two LEDs.
NOTE:
4-node systems—Cluster Interconnect Link ports are used to connect nodes together.
2-node system—Cluster Interconnect Link ports are not used and LEDs should always be
off.
Figure 8 Cluster Interconnect Link ports LEDs location
Table 7 Node Cluster Interconnect Link ports LEDs description
LED Function
1
Fault
2
Status
LED Troubleshooting
Incorrectly configured interconnect link cables result in the port amber LED being on.
Flashing amber LEDs can be caused by any of the following:
Cluster link cabling error
Controller node in wrong slot
Serial number mismatch between controller nodes
Appearance
State
Amber
On
Flashing
Off
Green
On
Off
Indicates
Fault—No link established
1. Interconnect link cabling error
2. Controller node in wrong slot
3. Serial number mismatch between controller nodes
No fault
Link established
No link established
Controller Nodes