Host/Ethernet Cables; Cabling Expansion Cabinets - HP HPE 3PAR StoreServ 8000 Installation Manual

Table of Contents

Advertisement

Host/Ethernet Cables

WARNING!
Each controller node supports one Ethernet connection to a switch or hub. Separate
connections from the Ethernet switch or hub to at least two controller nodes are required to
support redundancy. With redundancy, one IP address is shared between the two
connections, and only one network connection is active at a time. If the active network
connection fails, the IP address is automatically moved to the surviving network connection.
At a minimum, the system requires one Fibre Channel (or iSCSI) connection from a host
computer to a controller node. Hewlett Packard Enterprise recommends separate connections
from each host computer to each of the controller nodes in the system, with connections
distributed evenly across all controller nodes.
Table 26 External controller node connections
Connection Type
Ethernet
Fibre Channel
Maintenance
Table 27 (page 80)
cable size and port speed.
Table 27 Cable limitations for FC host connectivity
Cable Size
50 micron
50 micron
50 micron

Cabling Expansion Cabinets

For more information about cabling drive enclosures (SAS), before you continue to cable the
system, see the HPE 3PAR StoreServ 8000 Storage Cabling Configuration Guide at:
http://www.hpe.com/info/storage/docs
80
System Cabling
Minimum Configuration
Connection from the Ethernet switch or hub
to two controller nodes
Connection from a host computer to one
controller node
None
describes the maximum supported Fibre Channel cable length based on the
Speed
4 Gb/s
8 Gb/s
16 Gb/s
Recommended Configuration
See the section Supported Network
Topologies in HPE 3PAR StoreServ 8000
Storage Site Planning Manual.
Separate connections from host computers
to each controller node, through a switch,
with connections distributed evenly across
all controller nodes
Example: SAN Switch A connected to even
ports and SAN Switch B connected to odd
ports.
NOTE:
To provide redundancy and to
permit online software upgrades, both
controller nodes in a controller node pair (for
example, controller nodes 0 and 1 or
controller nodes 2 and 3) must maintain
connections to each host server.
Varies according to system and network
configuration
Cable Length Limit
150 meters
50 meters
35 meters

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents