Pull out the piston rod and push it back in numerous times
while pressing it to one side slightly.
✓ Air bubbles emerge and the cartridge is bled.
-
Keep bleeding until no more air bubbles emerge.
✓ The piston rod automatically moves out to the center of
the full stroke.
Info
When fully bled, the correct air chamber length is
202090-10
achieved.
-
Position the spring.
-
Pull the spring downward. Mount screw cap@).
Info
When assembling, ensure that the screw caps are cor­
rectly mounted according to the hydrostop needles.
Rebound damping side - red hydrostop needle, screw
cap with mark REB.
Compression damping side - silver hydrostop needle,
screw cap with mark COMP.
-
Mount the open end wrench on the hexagonal part.
-
Hold the open end wrench. Tighten screw cap @).
Guideline
Screw cap on piston
rod
I
Mounting tool (T14047) (!!:!Ip. 324)
-
Push the outer tube upward.
-
Clamp the outer tube in the area of the lower triple clamp.
I
Clamping stand (T1403S)
-
Tighten screw cap @).
Guideline
Cartridge on outer
tube
I
201701-11
Mounting tool (T14047)
-
Mount the adjuster. Mount and tighten screw@).
Guideline
I
Screw, adjuster
201700-11
6 FORK, TRIPLE CLAMP
M8x0. 75
18 Nm (13.3 lbf ft)
(!!:!I
p. 324)
M51x1 .5
40 Nm (29.5 lbf ft)
(!l.,!l
p. 324)
I M4x0.5
I 2.5 Nm (1 .84 lbf ft)
35