Removing A Sdram Sodimm - Cisco NPE-175 Installation And Configuration Manual

Network processing engine and network services engine
Table of Contents

Advertisement

Removing and Replacing the NPE or NSE

Removing a SDRAM SODIMM

This section provides a procedure for removing the small outline dual in-line memory module (SODIMM)
on the NPE-400.
Follow these steps to remove the existing SODIMM:
Remove the NPE-400 from the system.
Step 1
Place the NPE-400 on an antistatic mat or pad and ensure that you are wearing an antistatic device, such
Step 2
as a wrist strap.
Locate the SODIMM (see
Step 3
Figure 9-13
2
3
4
1
2
3
4
5
6
Locate the SODIMM standoff screw and use a Phillips screwdriver to remove it.
Step 4
Network Processing Engine and Network Services Engine Installation and Configuration
9-18
Figure
Location of SDRAM SODIMM on the NPE-400
1
5
Temperature sensor (U31)
Keying post
RM7000 microprocessor
System controller
Captive installation screw
Handle
9-13).
6
7
Midplane connectors
8
Boot ROM (U7)
9
Temperature sensor (U6)
10 SODIMM (J1)
11 Standoff and screw
Chapter 9
Removing and Installing the NPE or NSE
7
8
9
10
11
OL-4448-12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents