Bosch wLSN System Reference Manual page 41

Wireless local securitynetwork
Table of Contents

Advertisement

wLSN
Testing and Enabling When Only the Low-temperature Sensor
is Required
During the Point Test, test the low-temperature sensor. Refer to
Table 5.17 for instructions.
The system announces "Point xx was tested."
Do not connect the water sensor probe.
Sensor
Water
Low-temperature
Table 5.17 Testing and Enabling Procedures
Figure 5.14 Enabling the Water Probe and Low-Temperature Functions
Callout
1
2
Bosch Security Systems, Inc.
To test and enable:
Select one of the following methods:
Short the water probe pins for at least 5 sec.
Refer to Figure 5.14.
Submerge the water probe in water for at least
5 sec.
Short the "T" pads for at least 5 sec. Refer to
Figure 5.14.
1
Description
Probes for water sensor
"T" pads for low-temperature sensor
System Reference Guide
wLSN Devices | en
2
F01U138553 | 01 | 2010.05
41