Bosch wLSN System Reference Manual page 27

Wireless local securitynetwork
Table of Contents

Advertisement

wLSN
Figure 5.6 Single EOL Resistor Option
Callout
1
2
Alarm Resistor and Tamper Option
Place a maximum of five normally-closed contacts in series
with the 2.2 k-ohm EOL resistor. Each contact has either a
1.5 k-ohm or 2.2 k-ohm resistor across it. Refer to Figure 5.7.
Do not use contacts across the loop. The zone recognizes that
one or more of the contacts is opened, but not which ones or
how many.
Figure 5.7 Alarm Resistor and Tamper Option
Callout
1
2
3
4
Bosch Security Systems, Inc.
1
Description
Normally-open (NO)
Normally-closed (NC)
1
Description
1.5 k-ohm or 2.2 k-ohm alarm resistor
1.5 k-ohm or 2.2 k-ohm alarm resistor
(Optional: up to four additional alarm resistors allowed)
2.2 k-ohm EOL resistor
Normally-closed tamper switch (optional)
System Reference Guide
wLSN Devices | en
2
2
3
4
F01U138553 | 01 | 2010.05