Komatsu H75051 Operation & Maintenance Manual page 137

Wheel loader
Table of Contents

Advertisement

OPERATION
1.
Select "Auto Idle Stop Timer Setting" on "Machine Setting
and Information" menu, and press ENTER switch (1).
2.
Select the operating time of the auto idle stop, and press ENTER switch (1).
The operating time can be selected from 3 minutes to 60
minutes.
REMARK
Selecting "OFF" disables operation of the auto idle stop.
3.
If the idle state is continued up to 30 seconds before the
current auto idle stop timer setting, the countdown screen
is displayed on the standard screen.
If you increase the engine speed or set the directional lev-
er or directional selector switch to any position other than
NEUTRAL (N) at this point, the countdown is stopped and
the screen returns to the standard screen.
4.
If the idle state is further continued and the countdown
reaches 0 seconds, the engine stops.
The work equipment is locked as well after the engine is
stopped.
Turn the unnecessary switches to OFF position to prevent
the battery to run out.
REMARK
When the auto idle stop starts while the parking brake is off, re-
lease the parking brake by turning it on once and turning it off
again.
When restarting the engine, turn the starting switch key as usual.