Komatsu H75051 Operation & Maintenance Manual page 100

Wheel loader
Table of Contents

Advertisement

EXPLANATION OF COMPONENTS
CLOCK
The clock indicates the current time.
AFTERTREATMENT DEVICES REGENERATION PILOT LAMP
Exhaust gas temperature may increase higher than the previous models during the aftertreatment
devices regeneration. Stay away from the exhaust pipe outlet to prevent yourself from getting burnt.
Also, keep combustible materials away from the exhaust pipe outlet to prevent a fire.
If there is a thatched roof, dead leaves, paper, or other combustible matter near the machine, see
"HANDLE Komatsu Diesel Particulate Filter (KDPF) (3-124)".
Aftertreatment devices regeneration display indicates the re-
generation state of the aftertreatment devices.
(A): Lights up during regeneration of the aftertreatment devi-
ces. It goes out when the regeneration is completed.
(B): Lights up when KDPF is set to regeneration disable.
REMARK
The lighting cycle becomes shorter when the ambient tem-
perature is lower or working load is smaller.
Even if the aftertreatment devices regeneration is disabled,
when the manual stationary regeneration is necessary,
KDPF soot accumulation caution lamp lights up. If KDPF
soot accumulation caution lamp lights up, cancel the re-
generation disable setting and perform manual stationary
regeneration.
For the procedures of cancellation of regeneration disable
setting, and setting of manual stationary regeneration, see
"HANDLE Komatsu Diesel Particulate Filter (KDPF)
(3-124)".
SECONDARY STEERING PILOT LAMP
When the secondary steering pilot lamp is lit in green while the
engine is running or the machine is operating, it is normal.
If it does not light up, there is a trouble in the secondary steer-
ing circuit.
Move the machine to a safe place, stop the engine, and per-
form the inspection and maintenance.
3-34
k
k
CAUTION
OPERATION

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wa270-8H83001

Table of Contents