Furuno VR-7000S Installation Manual page 87

Voyage data recorder
Hide thumbs Also See for VR-7000S:
Table of Contents

Advertisement

7. A confirmation window appears; click the [OK] button to start uploading to the
VDR.
8. Click the [Write] button.
9. The message "VDR will be rebooted. Continue?" appears. Click the [OK] button
to continue.
You are logged out of the VDR Maintenance Viewer. The reboot takes several
minutes.
10. After the reboot, press the MENU/ESC key to open the main menu on the base
screen of the RAP (Remote Alarm Panel).
11. Use the cursorpad (
[Enter Password] pop-up window appears.
12. Press
,
,
,
13. Use the cursorpad (
ENT key.
14. Use the cursorpad (
When [Brilliance Sync Function] is set to [ON], the menu items for the brilliance
sharing ([Brilliance Sync] and [Brilliance Sync Settings]) appear on the [Settings]
menu.
15. Press the MENU/ESC key to go back to the [Settings] menu.
16. Use the cursorpad (
17. Use the cursorpad (
18. Adjust the brilliance of the EC-3000 units, then confirm that the RAP brilliance
changes accordingly.
Consistency check
Open the event log on the VDR Maintenance Viewer to check the consistency of the
brilliance sharing setting between DCU and RAP. For how to open the event log, see
the Instruction Manual (OME-44852).
• When the startup event log is "Brilliance sync function settings are the same.", the
setting consistency is correct.
• When the startup event log is "Brilliance sync function settings are difference.", the
brilliance sharing setting is different between the DCU and RAP. Check the settings
for the DCU and RAP.
or
) to select [Settings], [Servicemen Settings] in order.
, MENU/ESC, ENT in order.
or
) to select [Brilliance Sync Function] then press the
or
) to select [ON] then press the ENT key.
or
) to select [Brilliance Sync] then press the ENT key.
or
) to select [ON] then press the ENT key.
3. SETTING UP THE EQUIPMENT
3-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vr-7000

Table of Contents