2. WIRING
Input type (MC-3010A)
Select the type of the analog data input, power voltage or power current. When chang-
ing the input type, turn off the MC-3010A and on again to put change in effect.
Note 1: For current input, use the AWG wire for jumper.
Note 2: The input must not exceed the range of the input voltage, to prevent malfunc-
tion.
-Setting for voltage input: -10 V to +10 V or 0 to 10 V (depending on the setting)
-Setting for current input: 4 mA to 20 mA.
• Power voltage: Input the amount of power voltage change to the operational ampli-
fier.
Voltage
source
Load
• Power current: Pass the power current to the shunt resistor, 1 k /parallel (com-
bined resistance: 500 ) to input the amount of voltage change at the both ends of
the resistor to the operational amplifier.
Current
source
Load
2-32
AN- IN
AN- GND
CURR - JP1
CURR - JP2
Jumper: open
1kΩ 1% 0.5Wx2
AN-IN
AN-GND
CURR-JP1
CURR-JP2
Jumper short
1kΩ 1% 0.5Wx2
AN +15V
+15V
+VS1
Vin
+VS2
ISO122
OutGnd
- VS2
InGnd
- VS1
GND
- 15V
AN GND AN - 15V
AN +15V
+15V
+VS1
Vin
+VS2
ISO122
OutGnd
- VS2
InGnd
- VS1
GND
- 15V
AN GND AN - 15V