Junction Box If-8530 (Option) - Furuno VR-7000S Installation Manual

Voyage data recorder
Hide thumbs Also See for VR-7000S:
Table of Contents

Advertisement

2. WIRING
2.11

Junction Box IF-8530 (Option)

When the junction box IF-8530 is connected to the VDR, update the program version
of the junction box to ver. 2450113-01.01 or later. To update the program, prepare the
items shown in the table below.
Update program
Cable between a PC and
junction box
Manual for how to update
the program
The items above and IF-8530 is included in the optional IF-8530 version up kit (OP24-
48).
2.11.1
Location of connectors
Connect the serial, analog and digital signals to the terminal boards or connectors in
the junction box. Use the 2.5 mm
For serial and analog signal input, the DIP switch setting is required (see
section 2.11.2).
DCU
CH1: No use.
Digital
Channels
2-38
Item
Download it from Furuno Technet.
Type: JEC9-XH4-#26-L2500, Code No.: 000-170-945-10
Type: C42-01406-*, Code No.: 000-190-046-1*
2
Location of connectors
Serial channels
CH1
CH3
CH4
CH5
CH6
Description
or AWG14 wires to connect the signals.
CH7
CH8
CH1
CH2
DC 24V IN
DIP switch (from left):
S5 (Keep the default)
S4 (Baud rate 1)
S3 (Baud rate 2)
S2 (Analog 1)
S1 (Analog 1)
Analog
channels

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vr-7000

Table of Contents