Pin
Signal name
#
1
DC12V_OUT
2
DIGI_IN7
3
DIGI_RTN7
4
GND (DC12V)
5
DC12V_OUT
6
DIGI_IN8
7
DIGI_RTN8
8
GND (DC12V)
2.8.5
MC-3010A/3020D jumper setting
This section shows how to set the MC-ANLG Board (24P0115, for MC-3010A) and
MC-DIN Board (24P0116, for MC-3020D).
J3
J4
J5
MC-ANLG Board (24P0115)
Setting MODBUS addresses
Use the rotary switch U18 to set the MODBUS address with a digit of number from "0".
When multiple sensor adapters are connected to the MC-3000S, the same number
cannot be used among them. (The same number can be shared between the MC-
3000S and a sensor adapter.)
Setting termination resistors
Use the jumper block J25 to set the termination resistor on/off for the MODBUS com-
munication on the connector J1. For the first and last sensor adapter in a series, their
termination resistors should be set to ON. If not, communication between sensor
adapters is not possible.
Jumper block J25
1-2
2-3
1-2
2-3
Connector J6
In/
ACK7
Remarks
Out
contact
Out
ACK7 In
Pin #1-#2:
short
In
Out
MPYC-12
In
Out
ACK8 In
In
Out
In
J25
OPEN
Termination resistor: OFF (default setting)
SHORT
SHORT
Termination resistor: ON
OPEN
ACK7 voltage
No connection
MPYC-12
No connection
-
U18
MC-DIN Board (24P0116)
Connector J1
2. WIRING
ACK8
ACK8 voltage
contact
-
Pin #1-#2:
No connection
short
MPYC-12
MPYC-12
No connection
J25
2-35
U18

Advertisement