11. OPTIONS AND AUXILIARY EQUIPMENT
11.10 Power Factor Improving DC Reactor
The power factor improving DC reactor increases the form factor of the servo amplifier's input current to
improve the power factor. It can decrease the power supply capacity. As compared to the power factor
improving AC reactor (FR-BAL), it can decrease the loss. The input power factor is improved to about 95%.
It is also effective to reduce the input side harmonics.
When connecting the power factor improving DC reactor to the servo amplifier, always disconnect the wiring
www.DataSheet4U.com
across P1-P2. If it remains connected, the effect of the power factor improving DC reactor is not produced.
When used, the power factor improving DC reactor generates heat. To release heat, therefore, leave a 10cm
or more clearance at each of the top and bottom, and a 5cm or more clearance on each side.
Servo Amplifier
MR-J3-10B
20B FR-BEL-0.4K
MR-J3-40B
MR-J3-60B
70B FR-BEL-1.5K
MR-J3-100B
MR-J3-200B
MR-J3-350B
MR-J3-500B
MR-J3-700B
Note. When using the power factor improving DC reactor, disconnect the wiring across P
POINT
For the 100VAC power supply type (MR-J3- B1), the power factor improving
DC reactor cannot be used.
Terminal block - screw size G
Name plate
E
A or less
Power Factor
Improving DC
Reactor
A
B
110
50
FR-BEL-0.75K
120
53
130
65
FR-BEL-2.2K
130
65
FR-BEL-3.7K
150
75
FR-BEL-7.5K
150
75
FR-BEL-11K
170
93
FR-BEL-15K
170
93
2-F
L notch
Dimensions [mm]
C
D
E
F
94
1.6
95
6
102
1.6
105
6
110
1.6
115
6
110
1.6
115
6
102
2.0
135
6
126
2.0
135
6
132
2.3
155
6
170
2.3
155
6
5m or less
Servo Amplifier
FR-BEL
P
1
(Note)
P
2
11 - 40
H
B or less
F
Mounting leg
Mounting
Screw
Size
L
G
H
12
M3.5
25
M5
12
M4
25
M5
12
M4
30
M5
12
M4
30
M5
12
M4
40
M5
12
M5
40
M5
14
M5
50
M5
14
M8
56
M5
-P
.
1
2
[Unit: mm]
Used Power
Mass
Supply
[kg(lb)]
2
[mm
]
0.5
(1.10)
0.7
2
(1.54)
(AWG14)
1.1
(2.43)
1.2
(2.43)
1.7
3.5
(3.75)
(AWG12)
2.3
5.5
(5.07)
(AWG10)
3.1
5.5(AWG10)
(6.84)
3.8
8(AWG8)
(8.38)