11. OPTIONS AND AUXILIARY EQUIPMENT
11.1.5 SSCNET
(1) Model explanations
www.DataSheet4U.com
Numeral in the column of cable length on the table is a symbol put in the
which symbol exists are available.
Cable Model
MR-J3BUS M
MR-J3BUS M-A
(Note)
MR-J3BUS M-B
Note. For cable of 30m or less, contact our company.
(2) Specifications
SSCNET cable model
SSCNET cable length
Optical
Minimum bend
cable
radius
(cord)
Tension strength
Temperature range
for use (Note)
Ambient
External appearance
Note. This temperature range for use is the value for optical cable (cord) only. Temperature condition for the connector is the
same as that for servo amplifier.
cable
POINT
Do not see directly the light generated from CN1A CN1B connector of servo
amplifier or the end of SSCNET
may feel something is wrong for eye. (The light source of SSCNET
corresponds to class1 defined in JISC6802 or IEC60825-1.)
0.15m
0.3m
0.5m
1m
015
03
05
1
MR-J3BUS M
0.15m
25mm
70N
[mm]
2.2 0.07
cable. When the light gets into eye, you
Cable Length
3m
5m
10m
20m
30m
3
5
10
20
Description
MR-J3BUS M-A
0.3 to 3m
5 to 20m
Enforced covering cord: 50mm
Cord: 25mm
420N
140N
(Enforced covering cord)
-40 to 85
Indoors (no direct sunlight)
No solvent or oil
4.4 0.1
4.4 0.1
7.6 0.1
11 - 18
part of cable model. Cables of
Flex Life
40m
50m
Standard
Standard
30
40
50
Long flex
MR-J3BUS M-B
30 to 50m
Enforced covering cord: 50mm
Cord: 30mm
980N
(Enforced covering cord)
-20 to 70
4.4 0.4
7.6 0.5
Application
Remark
Using inside
panel standard
cord
Using outside
panel standard
cable
Using long
distance cable