11. OPTIONS AND AUXILIARY EQUIPMENT
(c) When fabricating the encoder cable
When fabricating the cable, prepare the following parts and tool, and fabricate it according to the wiring
diagram in (b). Refer to Section 11.8 for the specifications of the used cable.
www.DataSheet4U.com
(3) MR-J3JCBL03M-A1-L MR-J3JCLB03M-A2-L
The servo amplifier and servo motor cannot be connected with these cables only. The servo motor side
encoder cable (MR-EKCBL
Parts/Tool
Connector set
MR-ECNM
For CN2 connector
Connector housing: 54593-1011
Cover A: 54594-1015
Cover B: 54595-1005
Shell cover: 58935-1000
Shell body: 58934-1000
Cable clamp: 58937-0000
Screw: 58203-0010
(Molex)
M-L/H) is required.
Cable
Cable Model
Length
MR-J3JCBL03M-A1-L
0.3m
MR-J3JCBL03M-A2-L
Description
Junction connector
Housing: 1-172161-9
Connector pin: 170359-1
(Tyco Electronics or equivalent)
Cable clamp: MTI-0002
(Toa Electric Industries)
Protective
Flex Life
Structure
IP20
Standard
11 - 11
Application
For HF-MP HF-KP servo motor
Load side lead
Use in combination with MR-EKCBL
M-L/H.
For HF-MP HF-KP servo motor
Opposite-to-load side lead
Use in combination with MR-EKCBL
M-L/H.