Error/warning display
F77
F96
FA8
FC8
FE1
FE2
FE3
FE4
FE5
FE6
FE7
FE8
FE9
FF0
FF1
FF2
FF3
FF4
FF5
FF6
FF7
FF8
FH0
FH1
FH2
FH3
FJ0
FJ1
FL1
FL2
Note
f The self-diagnosis display and the details of the malfunction may vary.
f For errors and warnings that are not described in the table, consult your dealer.
r Measure for error and warning
Action
number
1
Clean the air filter unit.
2
The operating environment temperature is too high. Use the projector in an appropriate operating environment temperature
The operating environment temperature is too high, or the air exhaust port may be blocked. Use the projector in an
3
appropriate operating environment temperature
4
The operating environment temperature is too low. Use the projector in an appropriate operating environment temperature
5
Attach the air filter unit.
6
The input supply voltage is low. Use electric wiring that can sufficiently withstand the power consumption of the projector.
7
Battery replacement is required. Consult your dealer.
8
If the display does not clear after switching the main power off and on, consult your dealer.
*1 Refer to "Operating environment temperature" (x page 216) for the operating environment temperature of the projector.
194 - ENGLISH
Chapter 5 Maintenance — Self-diagnosis display
LD driver fan warning
Lens mounter error
Light source 1 error
Light source 2 error
Radiator fan 1 error
Radiator fan 2 error
Radiator fan 3 error
Radiator fan 4 error
Radiator fan 5 error
Radiator fan 6 error
Exhaust fan 1 error
Exhaust fan 2 error
Intake fan 1 error
Intake fan 2 error
Color prism fan 1 error
Color prism fan 2 error
Color prism fan 3 error
Optical engine exhaust fan 1 error
Optical engine exhaust fan 2 error
Circuit intake fan 1 error
Circuit intake fan 2 error
LD driver fan error
Phosphor wheel 1 error SUB
Phosphor wheel 1 error FPGA
Phosphor wheel 2 error SUB
Phosphor wheel 2 error FPGA
Liquid cooling pump 1 error
Liquid cooling pump 2 error
Light source 1 unit error
Light source 2 unit error
Details
Measure
. Or remove any objects that are blocking the air exhaust port.