E. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards:
• Pipe measurements are shown using the effective length
of pipe. See Section 12.A (Figure 12.1) for information
on effective length of pipe components.
• Horizontal terminations are measured to the outside
mounting surface (flange of termination cap). See
Figure 4.6.
• Vertical terminations are measured to top of last section
of pipe. See Figure 4.7.
• Horizontal pipe installed level with no rise.
Figure 4.6 Measure to Outside Mounting Surface
Figure 4.7 Measure to Top of Last Section of Pipe
20
Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. L • 4/19
MEASURE TO SHADED SURFACE