Heat & Glo SUPREME-N-I30AU Owenrs Manual
Heat & Glo SUPREME-N-I30AU Owenrs Manual

Heat & Glo SUPREME-N-I30AU Owenrs Manual

Gas and propane heater
Hide thumbs Also See for SUPREME-N-I30AU:
Table of Contents

Advertisement

Models:
SUPREME-N-I30AU
SUPREME-P-I30AU
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT USE OR STORE FLAMMABLE
MATERIALS NEAR THIS APPLIANCE.
• DO NOT SPRAY AEROSOLS IN THE VICIN-
ITY OF THIS APPLIANCE WHILE IT IS IN
OPERATION.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• DO NOT PLACE ARTICLES ON OR AGAINST THIS
APPLIANCE.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
WARNING! DO NOT modify this appliance.
SAI Global
Ref No GSCS20181
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo SUPREME-N-I30AU

  • Page 1 fi re department. • Installation and service must be performed WARNING! DO NOT modify this appliance. by a qualifi ed installer, service agency, or the gas supplier. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 2 Save this manual for future reference. Heat & Glo, a brand of Hearth & Home Technologies, Inc. 7571 215 Street West, Lakeville, MN 55044 Copyright 2011 • Printed in U.S.A. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 3: Congratulations

    The model information regarding your specifi c fi replace can be found on the rating plate usually located in the control area of the fi replace. Type of Gas SAI Global Certification Nº: DMS (mm) Model Number Serial Number xxxx-xxx Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 4: Table Of Contents

    E. Electrical Outlet Box ......20 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 5: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645C 12-29-10 Page 1 of 2 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645C 12-29-10 Page 2 of 2 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 7: Listing And Code Approvals

    DMS 52 (1.61 mm) Pilot Injector .020 .0121 An in-line regulator MUST be installed if the gas pressure exceeds 3.4 kPa. Failure to install a regulator could damage valve. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 8: User Guide

    REQUIRED ISOLATION SWITCH: AS5601 LOCATION WITHIN 1 METRE OF FIREPLACE, SUBJECT TO MANTEL PIECE, ETC. CHECK TO ENSURE IT REMAINS CLEAR ON ANY MANTEL PIECE INSTALLATION. Figure 2.1 General Operating Parts Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 9: Clear Space

    3. The control module has safety feature that automatically shuts down the fi replace after 9 hours of continuous operation without receiving a command from the RC300 remote. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 10 This is required for servicing and/or resetting the control module in the event of a control module LOCK-OUT. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 11: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 12: After Appliance Is Lit

    Delay from ON command to burner ignition of the burner fl ame. The delay is part of the pilot rectifi cation process and does not ignition affect performance. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 13: Maintenance And Service

    • Carefully set fi xed glass assembly in place on appliance. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 14: Maintenance Tasks-Service Technician

    Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 15: Installer Guide

    SECTION 5.B AND 11.A SURROUND OR FRONT NOT SHOWN SECTION 2.D AND 12.J. HEARTH EXTENSION GAS LINE (SECTION 9) ACCESS THROUGH EXISTING MASONRY OR WOODBURNING FIREPLACE Figure 4.1 Typical System Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 16: Design And Installation Considerations

    1/2 - 3/4 inch length, #6 or #8 Self-drilling screws Caulking material (300° F minimum continuous exposure rating) Caulking material (1200° F or higher minimum continuous exposure rating) Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 17: Fireplace Size Requirements

    * Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum fi replace height for bends in vent pipe. In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B). Figure 5.1 Fireplace Opening Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 18: Mantel And Wall Projections

    fi rebox. Combustible facings must not extend behind the insert surround. For non-combustible material specifi cations refer to Section 1.E. Figure 5.3 Mantel Clearances or Other Combustibles Above Appliances Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 19: Termination Locations

    53.1°-56.3° ............2 130 56.3°-59.0° ............2 290 59.0°-60.3° ............2 440 *910 mm minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 20: Installation Preparation

    fi replace to allow removal of the insert for future servicing needs. An in-line regulator MUST be installed if the gas pressure exceeds 3.4 kPa. Failure to install a regulator could dam- age valve. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 21: Installing Vent Pipe And Appliance

    INLET AIR STARTING COLLAR NOTE: TO ACHIEVE OPTIMUM PERFOR- MANCE OF INSERT, MINIMIZE OR AVOID BENDS IN EXHAUST VENT PIPE. STARTING COLLAR BRACKET EXHAUST STARTING COLLAR Figure 8.1 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 22: Placing, Securing And Leveling The Appliance

    See individual door instrucitons for reference. • Secure collar slide plate to appliance by placing locking handle into position with locking tabs (see Figure 8.1) and secure with #8 screw. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 23: Installing Adaptor And Termination Cap

    Remove 457mm x 457mm fl ashing on cap by removing 3 screws. Connect both the LINK-ZC-ADPB to Class A Pipe and the termina- tion cap to the LINK-ZC-ADPB with the self tapping screws provided. Figure 8.6 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 24 THIS IS A BALANCED FLUE HEATER AND REQUIRES THE USE OF BOTH FLUE LINERS AND MUST TERMINATE TO THE CAP. MINIMUM 6 mm NON-COMBUSTIBLE BASE (UNDER UNIT) Figure 8.7 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 25: Vent Kits Components

    fi re. LINK-DV30B For alternative installations, other than depicted, contact your dealer for further information. FLASH-DAMP LINK-ZC-ADP FLEX3-CNCT DV-46DVA-GK Figure 8.8 Direct Vent Flex Liner Accessory Kits Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 26: Flue Termination

    (depth without using additional pipe sections) (192 mm) MINIMUM SLP-TRAP2 Supreme-N-AU Rear Vent Depth Supreme-P-AU 5-1/2 in. (152 mm) to 9-1/2 in. (241 mm) Figure 8.10 Termination Cap Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 27 NOTE: Tape all SLP pipe connec- tions with aluminum foil tape rated to a minimum of 300° F (149° C). Figure 8.12 Optional SLP venting confi guration - Horizontal Termination Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 28 Sealant must have a mini- mum explosure rating of 1200° F (649° C). MINIMUM 6 mm NON-COMBUSTIBLE BASE (UNDER UNIT) Figure 8.13 Optional SLP Venting Confi guration - Vertical Termination Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 29 HEBEL BLOCKS QUALITY 24 Note: Unit base to have min. 6 mm non-combustible base. If using standard front, box depth can be reduced to 360 mm internal. Figure 8.14 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 30 MINIMUM 6 mm NOTE: Tape all SLP pipe connec- NON-COMBUSTIBLE tions with aluminum foil tape rated BASE (UNDER UNIT) to a minimum of 300° F (149° C). Figure 8.15 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 31 Seal connection points for duct- ing. Sealant must have a mini- mum explosure rating of 1200° F (649° C). MINIMUM 6 mm NON-COMBUSTIBLE BASE (UNDER UNIT) Figure 8.16 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 32 Figure 8.17 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 33: Gas Information

    DMS 52 (1.61 mm) Pilot Injector .020 .0121 An in-line regulator MUST be installed if the gas pressure exceeds 3.4 kPa. Failure to install a regulator could damage valve. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 34: Electrical Information

    OPTIONAL ON/OFF WALL SWITCH ORANGE GREEN (PILOT) (MAIN) BLACK BATTERY PACK 6V DC (C X 4) BROWN 220/240 V INCOMING POWER GROUND Figure 10.1 IPI Wiring Diagram RC300AU Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 35: Optional Accessories Requirements

    2187-198 GREEN SURROUND (MAIN) SWITCH VALVE OPTIONS NG 2166-302 LP 2166-303 * NOTE: GROUND FROM WIRE HARNESS MUST BE ATTACHED TO UNPAINTED METAL Figure 10.2 Fan Wiring Diagram Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 36: Rem300-Hng-Au Instructions

    The RC300AU is approved for interior installation and should not be used in exterior applications. • Keep remote control out of reach of children. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 37 Figure 10.5. Remote in Housing Figure 10.3. Temperature Scale 5. Close the housing door. See Figure 10.6. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 38: Fan Installation

    7 min. ON, 12 min. OFF FAN CORD FAN CORD LEARN BUTTON Figure 10.9. Programming RC300AU AUX 300 AUX 300 MODULE MODULE Figure 10.8 Plug Fan into AUX300CE Module Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 39 Use the SELECT button to select the current Select feature. Use the UP and DOWN arrows to toggle through the menu functions and value selec- tions in the submenus. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 40: Adjusting Flame Height

    ON the AUX1 and AUX2 settings will be restored to NOTICE: The system will remember the previous FLAME the previous ON setting. HEIGHT setting and will automatically adjust after 10 seconds. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 41 Turn off power to the fi replace (if back-up batteries are is disabled. not installed): • Locate house circuit breaker for fi replace. • Turn off the circuit breaker. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 42 At control module, turn off fi replace by sliding the ON/OFF/RE- Remote control or control MOTE switch to OFF. Warning! Risk of Burns! Fireplace is hot. module failure Use caution when accessing module. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 43: Finishing

    Combustible facings must not extend behind the insert surround. For non-combustible material specifi cations refer to section 1.E. Figure 11.1 Clearances to Mantels or other Combustibles above Appliance Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 44: Appliance Setup

    • Place lava rock in front of and to the sides of the burner. Figure 12.2 Placement of Embers PLACE LAVA ROCK IN SHADED AREA ONLY Figure 12.1 Placement of Lava Rock Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 45: Install The Log Assembly

    Log #2 (SRV2206-705): Position Log #2 as shown in Figure 3. Mate the slot located on the bottom of Log #2 (Figure 4) with the log pin located on the surface of the burner. Rotate the right end of Log #2 clockwise, until it comes into contact with the grate tine. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 46 Log #6 SRV(2206-706): Position Log #6 as shown in Figure 8. See Figure 7 for additional references. Rest the left end of Log #6 on the fl at spot of Log #3. Position the nose of Log #6 on the fork of Log #5. 2206-935B Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 47: Fixed Glass Assembly

    Air Shutter Settings latches. Natural Gas Propane Gas SUPREME-I30AU 9.5 mm 13 mm Figure 12.3 Fixed Glass Assembly Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 48: Decorative Fronts And Surrounds

    BK= Black, GT= Graphite, GY= Fog Gray, RED= High gloss red, EB= High gloss ebony Refer to the installation instructions supplied with the doors and the surrounds. Contact dealer for further information. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 49: Optional Accessories

    TEMP SETTING THERMOSTAT CHILD LOCK FLAME HEIGHT INDICATOR FAN SPEED TRANSMISSION INDICATOR ADJUSTABLE AUXILIARY LOW BATTERY ADJUSTABLE INDICATOR OUTPUT (ON/OFF) FUNCTION LEVEL INDICATOR ROOM TEMP DISPLAY TIMER DISPLAY/FUNCTION Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 50: Troubleshooting

    D. Pilot valve solenoid. Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 51 B. Shutter Setting Check to assure correct shutter setting for your model and gas type. C. Gas Type Assure correct fuel matches unit gas model and components. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 52: Maintenance Tasks

    2. Replace batteries in remote transmitters and battery-powered receivers. Carbon Deposition 1. Appliances incorporating a live fuel effect, and designed to operate with luminous fl ames, may exhibit slight carbon deposition. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 53: Reference Materials

    SUPREME-I30-AU SUPREME-I30-AU Location Location Inches Millimeters Inches Millimeters 20-3/16 4-13/16 30-1/2 27-7/16 2-1/4 12-13/16 3-15/16 20-1/2 5-3/16 17-5/8 13-7/8 1-3/4 10-1/8 2-1/4 4-7/16 1-3/4 Figure 14.1 Appliance Dimensions Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 54: Service Parts

    Base Pan 2206-106 Grate Assemby 2206-016 Glass Door Assembly GLA-2206 2222-129 Control Panel Power Cord Assembly 2222-374 Blower Assembly GFK210-240V Additional service part numbers appear on following page. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 55 Aux300 CE 2166-340 15.16 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 500mA~10A 3/4” long Additional service part numbers appear on following page. Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 56 Touch up Paint TUP-GBK-12 Conversion Kit N P2N-I30AU Conversion Kit P N2P-I30AU Pilot Orifi ce N 2098-518 Pilot Orifi ce P 2098-512 Regulator N NGK-DXV-50 Regulator P LPK-DXV-50 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...
  • Page 57: Contact Information

    5647340, 5890485, 5941237, 5947112, 5996575, 6006743, 6019099, 6053165, 6145502, 6170481, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729 or other U.S. and foreign patents pending. 2000-945 Printed in U.S.A. - Copyright 2011 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. E • 6/11...

This manual is also suitable for:

Supreme-p-i30au

Table of Contents