Program Edit Mode
The CC Sequencer (CC SEQ) Page
State
Use the State parameter to turn the CC Sequencer On or Off.
In Program Mode, the State parameter can also be controlled by pressing the CC SEQ
button in the front panel ARPEGGIATOR section.
In Multi Mode, State can be controlled in each Zone by the front panel CC SEQ button.
In each Multi, the CC SEQ button must be assigned on the Multi Edit Controls page of
each Zone using Destination 148 (CC Seq On/Off) with On Value 127 and Off Value 0.
State can also be controlled with other controllers on the Multi Edit Controls page by using
Destination 148 (CC Seq On/Off).
Number Steps
Use the Number Steps parameter to set the number of steps in the sequence.
Sync
When the State parameter is set to On, the Sync parameter determines when the CC
sequence will re-start.
When the Sync parameter is set to Free Run, the sequence begins playing as soon as the
program is selected, and it restarts whenever it reaches the end of the sequence.
When the Sync parameter is set to Every Note, the sequence begins playing as soon as the
program is selected, and it restarts whenever it reaches the end of the sequence, or whenever a
new note is played.
When the Sync parameter is set to All Keys Up, the sequence begins playing as soon as the
program is selected, and it restarts whenever it reaches the end of the sequence, or whenever
all keys have been released.
When the Sync parameter is set to Arp, the sequence begins playing only when the program's
arpeggiator is playing, and it restarts whenever it reaches the end of the sequence.
When the Sync parameter is set to Arp with Reset, the sequence begins playing only when
the program's arpeggiator is playing, and it restarts whenever it reaches the end of the
sequence, or whenever the program's arpeggiator restarts its sequence.
The AnyOther CCSeq setting only applies to Multi Mode. When the Sync parameter is
set to AnyOther CCSeq, the sequence begins playing as soon as the Multi is selected, and
it restarts whenever it reaches the end of the sequence, or whenever a CC Sequence for a
program in another Zone begins or restarts.